The basic examination of the magnetic shielding structure to use for a magnetic rotation angle sensor

Takeshi Musha, Hiroshi Inujima

Research output: Contribution to journalArticle

Abstract

The magnetic rotation angle sensor has more merits such as small-sized, low cost and the low power consumption than the optical sensor. But the magnetic rotation angle sensor has the demerit to be weak to the disturbance magnetic field applied from outside the sensor, so the magnetic rotation angle sensor needs magnetic shielding structure. We proposed the magnetic shielding structure of the parallel plate type which is the simpler technique to the magnetic shielding structure of enclosing the whole sensor with the magnetic substance. We confirmed that the parallel plate type has almost the same shielding ability as the magnetic shielding structure of enclosing the whole sensor with the magnetic substance at the magnetic detecting device. We have made a prototype and evaluated angle detection error with the disturbance magnetic field. As a result, we confirmed that the error is 0.06deg when 10mT disturbance magnetic fields hang over the sensor.

Original languageEnglish
Pages (from-to)570-575
Number of pages6
JournalIEEJ Transactions on Fundamentals and Materials
Volume138
Issue number11
DOIs
Publication statusPublished - 2018 Jan 1

Fingerprint

Magnetic shielding
Sensors
Magnetic fields
Magnetic devices
Error detection
Optical sensors
Shielding
Electric power utilization

Keywords

  • Magnetic sensor
  • Magnetic shielding
  • Rotation angle sensor

ASJC Scopus subject areas

  • Electrical and Electronic Engineering

Cite this

The basic examination of the magnetic shielding structure to use for a magnetic rotation angle sensor. / Musha, Takeshi; Inujima, Hiroshi.

In: IEEJ Transactions on Fundamentals and Materials, Vol. 138, No. 11, 01.01.2018, p. 570-575.

Research output: Contribution to journalArticle

@article{659156c87c6e4f5b859a32885ce454d8,
title = "The basic examination of the magnetic shielding structure to use for a magnetic rotation angle sensor",
abstract = "The magnetic rotation angle sensor has more merits such as small-sized, low cost and the low power consumption than the optical sensor. But the magnetic rotation angle sensor has the demerit to be weak to the disturbance magnetic field applied from outside the sensor, so the magnetic rotation angle sensor needs magnetic shielding structure. We proposed the magnetic shielding structure of the parallel plate type which is the simpler technique to the magnetic shielding structure of enclosing the whole sensor with the magnetic substance. We confirmed that the parallel plate type has almost the same shielding ability as the magnetic shielding structure of enclosing the whole sensor with the magnetic substance at the magnetic detecting device. We have made a prototype and evaluated angle detection error with the disturbance magnetic field. As a result, we confirmed that the error is 0.06deg when 10mT disturbance magnetic fields hang over the sensor.",
keywords = "Magnetic sensor, Magnetic shielding, Rotation angle sensor",
author = "Takeshi Musha and Hiroshi Inujima",
year = "2018",
month = "1",
day = "1",
doi = "10.1541/ieejfms.138.570",
language = "English",
volume = "138",
pages = "570--575",
journal = "IEEJ Transactions on Fundamentals and Materials",
issn = "0385-4205",
publisher = "The Institute of Electrical Engineers of Japan",
number = "11",

}

TY - JOUR

T1 - The basic examination of the magnetic shielding structure to use for a magnetic rotation angle sensor

AU - Musha, Takeshi

AU - Inujima, Hiroshi

PY - 2018/1/1

Y1 - 2018/1/1

N2 - The magnetic rotation angle sensor has more merits such as small-sized, low cost and the low power consumption than the optical sensor. But the magnetic rotation angle sensor has the demerit to be weak to the disturbance magnetic field applied from outside the sensor, so the magnetic rotation angle sensor needs magnetic shielding structure. We proposed the magnetic shielding structure of the parallel plate type which is the simpler technique to the magnetic shielding structure of enclosing the whole sensor with the magnetic substance. We confirmed that the parallel plate type has almost the same shielding ability as the magnetic shielding structure of enclosing the whole sensor with the magnetic substance at the magnetic detecting device. We have made a prototype and evaluated angle detection error with the disturbance magnetic field. As a result, we confirmed that the error is 0.06deg when 10mT disturbance magnetic fields hang over the sensor.

AB - The magnetic rotation angle sensor has more merits such as small-sized, low cost and the low power consumption than the optical sensor. But the magnetic rotation angle sensor has the demerit to be weak to the disturbance magnetic field applied from outside the sensor, so the magnetic rotation angle sensor needs magnetic shielding structure. We proposed the magnetic shielding structure of the parallel plate type which is the simpler technique to the magnetic shielding structure of enclosing the whole sensor with the magnetic substance. We confirmed that the parallel plate type has almost the same shielding ability as the magnetic shielding structure of enclosing the whole sensor with the magnetic substance at the magnetic detecting device. We have made a prototype and evaluated angle detection error with the disturbance magnetic field. As a result, we confirmed that the error is 0.06deg when 10mT disturbance magnetic fields hang over the sensor.

KW - Magnetic sensor

KW - Magnetic shielding

KW - Rotation angle sensor

UR - http://www.scopus.com/inward/record.url?scp=85055987182&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85055987182&partnerID=8YFLogxK

U2 - 10.1541/ieejfms.138.570

DO - 10.1541/ieejfms.138.570

M3 - Article

AN - SCOPUS:85055987182

VL - 138

SP - 570

EP - 575

JO - IEEJ Transactions on Fundamentals and Materials

JF - IEEJ Transactions on Fundamentals and Materials

SN - 0385-4205

IS - 11

ER -