The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components

T. M. Wright, T. Fukubayashi, A. H. Burstein

Research output: Contribution to journalArticle

46 Citations (Scopus)

Abstract

To study the mechanical behavior of a commercially available UHMWPE reinforced with carbon fibers, measurements of contact area, contact pressure and time-dependent deformation were made on tibial components from a contemporary total knee replacement loaded to physiological levels. For comparison, similar measurements were performed on identical components manufactured from plain UHMWPE. Contact area and pressure results reflected the increased stiffness of the carbon-UHMWPE material, with smaller contact areas and generally higher contact pressures versus the plain UHMWPE at the same load. Stresses in both materials under the contact area approached or exceeded the yield stesses for the materials when the physiological load was high or the radius of the femoral component indenter decreased (similar to flexion of the knee). Time-dependent deformation over a 24 h period was reduced significantly in the carbon-UHMWPE components for a high physiological load.

Original languageEnglish
Pages (from-to)719-730
Number of pages12
JournalJournal of Biomedical Materials Research
Volume15
Issue number5
Publication statusPublished - 1981 Sep
Externally publishedYes

Fingerprint

Ultrahigh molecular weight polyethylenes
Polyethylene
Fiber reinforced materials
Carbon fibers
Polyethylenes
Carbon
Knee prostheses
Loads (forces)
Stiffness
ultra-high molecular weight polyethylene
carbon fiber

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biomaterials

Cite this

The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components. / Wright, T. M.; Fukubayashi, T.; Burstein, A. H.

In: Journal of Biomedical Materials Research, Vol. 15, No. 5, 09.1981, p. 719-730.

Research output: Contribution to journalArticle

@article{9e912e586b7c408bbe6c9bdc168f681b,
title = "The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components",
abstract = "To study the mechanical behavior of a commercially available UHMWPE reinforced with carbon fibers, measurements of contact area, contact pressure and time-dependent deformation were made on tibial components from a contemporary total knee replacement loaded to physiological levels. For comparison, similar measurements were performed on identical components manufactured from plain UHMWPE. Contact area and pressure results reflected the increased stiffness of the carbon-UHMWPE material, with smaller contact areas and generally higher contact pressures versus the plain UHMWPE at the same load. Stresses in both materials under the contact area approached or exceeded the yield stesses for the materials when the physiological load was high or the radius of the femoral component indenter decreased (similar to flexion of the knee). Time-dependent deformation over a 24 h period was reduced significantly in the carbon-UHMWPE components for a high physiological load.",
author = "Wright, {T. M.} and T. Fukubayashi and Burstein, {A. H.}",
year = "1981",
month = "9",
language = "English",
volume = "15",
pages = "719--730",
journal = "Journal of Biomedical Materials Research - Part A",
issn = "1549-3296",
publisher = "Heterocorporation",
number = "5",

}

TY - JOUR

T1 - The effect of carbon fiber reinforcement on contact area, contact pressure, and time-dependent deformation in polyethylene tibial components

AU - Wright, T. M.

AU - Fukubayashi, T.

AU - Burstein, A. H.

PY - 1981/9

Y1 - 1981/9

N2 - To study the mechanical behavior of a commercially available UHMWPE reinforced with carbon fibers, measurements of contact area, contact pressure and time-dependent deformation were made on tibial components from a contemporary total knee replacement loaded to physiological levels. For comparison, similar measurements were performed on identical components manufactured from plain UHMWPE. Contact area and pressure results reflected the increased stiffness of the carbon-UHMWPE material, with smaller contact areas and generally higher contact pressures versus the plain UHMWPE at the same load. Stresses in both materials under the contact area approached or exceeded the yield stesses for the materials when the physiological load was high or the radius of the femoral component indenter decreased (similar to flexion of the knee). Time-dependent deformation over a 24 h period was reduced significantly in the carbon-UHMWPE components for a high physiological load.

AB - To study the mechanical behavior of a commercially available UHMWPE reinforced with carbon fibers, measurements of contact area, contact pressure and time-dependent deformation were made on tibial components from a contemporary total knee replacement loaded to physiological levels. For comparison, similar measurements were performed on identical components manufactured from plain UHMWPE. Contact area and pressure results reflected the increased stiffness of the carbon-UHMWPE material, with smaller contact areas and generally higher contact pressures versus the plain UHMWPE at the same load. Stresses in both materials under the contact area approached or exceeded the yield stesses for the materials when the physiological load was high or the radius of the femoral component indenter decreased (similar to flexion of the knee). Time-dependent deformation over a 24 h period was reduced significantly in the carbon-UHMWPE components for a high physiological load.

UR - http://www.scopus.com/inward/record.url?scp=0019620832&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0019620832&partnerID=8YFLogxK

M3 - Article

VL - 15

SP - 719

EP - 730

JO - Journal of Biomedical Materials Research - Part A

JF - Journal of Biomedical Materials Research - Part A

SN - 1549-3296

IS - 5

ER -