T1 - The efficacy of sinus plication in aortic valvuloplasty for bicuspid aortic valve
T2 - Experiments in a pulsatile flow simulation model
AU - Arimura, Satoshi
AU - Takada, Jumpei
AU - Nishimura, Gohki
AU - Nakama, Natsuki
AU - Kawasaki, Eita
AU - Matsuhama, Minoru
AU - Iwasaki, Kiyotaka
AU - Kasegawa, Hitoshi
AU - Kunihara, Takashi
N1 - Publisher Copyright:
© 2021 The Author(s). Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.
PY - 2021/10/1
Y1 - 2021/10/1
N2 - OBJECTIVES: Sinus plication has emerged as a promising tool that can lead to better stability in bicuspid aortic valve (BAV) repair. However, the mechanisms underlying the efficacy of this technique are unclear. We evaluated the hydrodynamic effect of sinus plication using the experimental pulsatile flow simulator and our original BAV model in vitro. METHODS: Based on the computed tomography data of a BAV patient who had undergone aortic valvuloplasty, a BAV model (group C, n = 6) was developed with bovine pericardium and vascular prosthesis (J-graft Shield Neo Valsalva 24 mm). We performed sinus plication (group SP, n = 6) in the BAV model and compared hydrodynamic data with the control model in the pulsatile flow simulator. Non-fused cusp angle, annulus diameter and effective height were measured by ultrasonography. RESULTS: The average flow was significantly increased in group SP compared to group C (4.24 ± 0.14 l/min vs 4.14 ± 0.15 l/min, respectively, P = 0.034). The mean transvalvular pressure gradient and regurgitant fraction were significantly decreased in group SP compared to group C (11.6 ± 4.3 mmHg vs 16.6 ± 5.0 mmHg, respectively, P = 0.009 and 14.1 ± 2.0% vs 17.4 ± 2.1%, respectively, P = 0.001). Ultrasound measurement indicated that non-fused cusp angle was significantly increased in group SP compared to group C (163.8° ± 9.2° vs 153.0° ± 4.6°, respectively, P = 0.012). CONCLUSIONS: Sinus plication in the BAV model significantly increased the commissural angle. It was effective in not only controlling regurgitation but also improving valve opening. These finding should be confirmed by evaluating cusp stress and/or long-term durability in the future studies.
AB - OBJECTIVES: Sinus plication has emerged as a promising tool that can lead to better stability in bicuspid aortic valve (BAV) repair. However, the mechanisms underlying the efficacy of this technique are unclear. We evaluated the hydrodynamic effect of sinus plication using the experimental pulsatile flow simulator and our original BAV model in vitro. METHODS: Based on the computed tomography data of a BAV patient who had undergone aortic valvuloplasty, a BAV model (group C, n = 6) was developed with bovine pericardium and vascular prosthesis (J-graft Shield Neo Valsalva 24 mm). We performed sinus plication (group SP, n = 6) in the BAV model and compared hydrodynamic data with the control model in the pulsatile flow simulator. Non-fused cusp angle, annulus diameter and effective height were measured by ultrasonography. RESULTS: The average flow was significantly increased in group SP compared to group C (4.24 ± 0.14 l/min vs 4.14 ± 0.15 l/min, respectively, P = 0.034). The mean transvalvular pressure gradient and regurgitant fraction were significantly decreased in group SP compared to group C (11.6 ± 4.3 mmHg vs 16.6 ± 5.0 mmHg, respectively, P = 0.009 and 14.1 ± 2.0% vs 17.4 ± 2.1%, respectively, P = 0.001). Ultrasound measurement indicated that non-fused cusp angle was significantly increased in group SP compared to group C (163.8° ± 9.2° vs 153.0° ± 4.6°, respectively, P = 0.012). CONCLUSIONS: Sinus plication in the BAV model significantly increased the commissural angle. It was effective in not only controlling regurgitation but also improving valve opening. These finding should be confirmed by evaluating cusp stress and/or long-term durability in the future studies.
KW - Aortic valvuloplasty
KW - Bicuspid aortic valve
KW - Bicuspid valve repair
KW - Sinus plication
UR - http://www.scopus.com/inward/record.url?scp=85119362704&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85119362704&partnerID=8YFLogxK
U2 - 10.1093/ejcts/ezab115
DO - 10.1093/ejcts/ezab115
M3 - Article
C2 - 33760025
AN - SCOPUS:85119362704
SN - 1010-7940
VL - 60
SP - 859
EP - 864
JO - European Journal of Cardio-thoracic Surgery
JF - European Journal of Cardio-thoracic Surgery
IS - 4
ER -