The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC

Akira Shimada, Yoshihiro Ide, Keiichiro Kondo

Research output: Chapter in Book/Report/Conference proceedingConference contribution

2 Citations (Scopus)

Abstract

In AC motor drive systems, the motor input voltage is limited by the maximum inverter output voltage, which restricts the motor performance. As one of the solutions, an unbalanced input voltage three level inverter can be applied to boost up the input voltage by means of energy storage devices, such as EDLCs. Applying EDLCs as energy storage devices, energy management is required through the whole operation of the motor because the energy density of EDLCs is not so high. In this paper, a method of energy management for EDLC and a method to determine the capacity of EDLC are revealed when the load profile are given with the inertial load.

Original languageEnglish
Title of host publicationSPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion
Pages649-653
Number of pages5
DOIs
Publication statusPublished - 2012 Oct 5
Externally publishedYes
Event21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion, SPEEDAM 2012 - Sorrento, Italy
Duration: 2012 Jun 202012 Jun 22

Other

Other21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion, SPEEDAM 2012
CountryItaly
CitySorrento
Period12/6/2012/6/22

Fingerprint

Energy management
Electric potential
Energy storage
AC motors

Keywords

  • EDLCs
  • energy storage device
  • inertial load
  • motor drive
  • three level inverter
  • unbalanced input voltage three level inverter

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Electrical and Electronic Engineering

Cite this

Shimada, A., Ide, Y., & Kondo, K. (2012). The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC. In SPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion (pp. 649-653). [6264490] https://doi.org/10.1109/SPEEDAM.2012.6264490

The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC. / Shimada, Akira; Ide, Yoshihiro; Kondo, Keiichiro.

SPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion. 2012. p. 649-653 6264490.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Shimada, A, Ide, Y & Kondo, K 2012, The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC. in SPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion., 6264490, pp. 649-653, 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion, SPEEDAM 2012, Sorrento, Italy, 12/6/20. https://doi.org/10.1109/SPEEDAM.2012.6264490
Shimada A, Ide Y, Kondo K. The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC. In SPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion. 2012. p. 649-653. 6264490 https://doi.org/10.1109/SPEEDAM.2012.6264490
Shimada, Akira ; Ide, Yoshihiro ; Kondo, Keiichiro. / The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC. SPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion. 2012. pp. 649-653
@inproceedings{3cac336d01d44484ae71049b7af6eafc,
title = "The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC",
abstract = "In AC motor drive systems, the motor input voltage is limited by the maximum inverter output voltage, which restricts the motor performance. As one of the solutions, an unbalanced input voltage three level inverter can be applied to boost up the input voltage by means of energy storage devices, such as EDLCs. Applying EDLCs as energy storage devices, energy management is required through the whole operation of the motor because the energy density of EDLCs is not so high. In this paper, a method of energy management for EDLC and a method to determine the capacity of EDLC are revealed when the load profile are given with the inertial load.",
keywords = "EDLCs, energy storage device, inertial load, motor drive, three level inverter, unbalanced input voltage three level inverter",
author = "Akira Shimada and Yoshihiro Ide and Keiichiro Kondo",
year = "2012",
month = "10",
day = "5",
doi = "10.1109/SPEEDAM.2012.6264490",
language = "English",
isbn = "9781467312998",
pages = "649--653",
booktitle = "SPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion",

}

TY - GEN

T1 - The relationship between output power and accumulated energy of the unbalanced input voltage three level inverter with the EDLC

AU - Shimada, Akira

AU - Ide, Yoshihiro

AU - Kondo, Keiichiro

PY - 2012/10/5

Y1 - 2012/10/5

N2 - In AC motor drive systems, the motor input voltage is limited by the maximum inverter output voltage, which restricts the motor performance. As one of the solutions, an unbalanced input voltage three level inverter can be applied to boost up the input voltage by means of energy storage devices, such as EDLCs. Applying EDLCs as energy storage devices, energy management is required through the whole operation of the motor because the energy density of EDLCs is not so high. In this paper, a method of energy management for EDLC and a method to determine the capacity of EDLC are revealed when the load profile are given with the inertial load.

AB - In AC motor drive systems, the motor input voltage is limited by the maximum inverter output voltage, which restricts the motor performance. As one of the solutions, an unbalanced input voltage three level inverter can be applied to boost up the input voltage by means of energy storage devices, such as EDLCs. Applying EDLCs as energy storage devices, energy management is required through the whole operation of the motor because the energy density of EDLCs is not so high. In this paper, a method of energy management for EDLC and a method to determine the capacity of EDLC are revealed when the load profile are given with the inertial load.

KW - EDLCs

KW - energy storage device

KW - inertial load

KW - motor drive

KW - three level inverter

KW - unbalanced input voltage three level inverter

UR - http://www.scopus.com/inward/record.url?scp=84866912828&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84866912828&partnerID=8YFLogxK

U2 - 10.1109/SPEEDAM.2012.6264490

DO - 10.1109/SPEEDAM.2012.6264490

M3 - Conference contribution

SN - 9781467312998

SP - 649

EP - 653

BT - SPEEDAM 2012 - 21st International Symposium on Power Electronics, Electrical Drives, Automation and Motion

ER -