Abstract

Generally, the main water pipeline is built through installing steel pipes or iron pipes inside a shield tunnel or NATM tunnel and filling the annular void to form an integrated structure. However, the problem of buckling of inner pipe exists for such a structure because the most of the existing filling technologies fail to produce a tightly fitted liner. When the water pipeline is built deep underground, the separated structure should be adopted in order to ensure the minimum cross section of the tunnel as well as the safety of water pipe. In this study, the buckling of stiffened water pipe used for separated structure is investigated. Firstly, the formulas of general buckling and local buckling are derived with Ritz method, and the methods of the formulas application are given in terms of the critical pressure calculation and the buckling behavior simulation. Secondly, the methods are verified by numerical analysis and existing experiments. Finally, the local buckling design method for separated water pipeline structure is proposed, taking into account of the buckling characters of a practical water pipeline.

Original languageEnglish
Pages (from-to)588-602
Number of pages15
JournalDoboku Gakkai Ronbunshuu A
Volume64
Issue number3
DOIs
Publication statusPublished - 2008
Externally publishedYes

Fingerprint

Water pipelines
Hydrostatic pressure
Buckling
Pipe
Tunnels
Steel pipe
Numerical analysis
Water
Iron

Keywords

  • Buckling behavior
  • Buckling design
  • Deep underground
  • Stiffened water pipe

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Mechanics of Materials
  • Mechanical Engineering
  • Building and Construction

Cite this

Theoretical study on buckling of deep water pipeline under external hydrostatic pressure. / Wang, Jianhong; Koizumi, Atsushi.

In: Doboku Gakkai Ronbunshuu A, Vol. 64, No. 3, 2008, p. 588-602.

Research output: Contribution to journalArticle

Wang, Jianhong ; Koizumi, Atsushi. / Theoretical study on buckling of deep water pipeline under external hydrostatic pressure. In: Doboku Gakkai Ronbunshuu A. 2008 ; Vol. 64, No. 3. pp. 588-602.
@article{c7b278c9c26043b7a3725926e56c6a6f,
title = "Theoretical study on buckling of deep water pipeline under external hydrostatic pressure",
abstract = "Generally, the main water pipeline is built through installing steel pipes or iron pipes inside a shield tunnel or NATM tunnel and filling the annular void to form an integrated structure. However, the problem of buckling of inner pipe exists for such a structure because the most of the existing filling technologies fail to produce a tightly fitted liner. When the water pipeline is built deep underground, the separated structure should be adopted in order to ensure the minimum cross section of the tunnel as well as the safety of water pipe. In this study, the buckling of stiffened water pipe used for separated structure is investigated. Firstly, the formulas of general buckling and local buckling are derived with Ritz method, and the methods of the formulas application are given in terms of the critical pressure calculation and the buckling behavior simulation. Secondly, the methods are verified by numerical analysis and existing experiments. Finally, the local buckling design method for separated water pipeline structure is proposed, taking into account of the buckling characters of a practical water pipeline.",
keywords = "Buckling behavior, Buckling design, Deep underground, Stiffened water pipe",
author = "Jianhong Wang and Atsushi Koizumi",
year = "2008",
doi = "10.2208/jsceja.64.588",
language = "English",
volume = "64",
pages = "588--602",
journal = "Doboku Gakkai Ronbunshuu A",
issn = "1880-6023",
publisher = "Japan Society of Civil Engineers",
number = "3",

}

TY - JOUR

T1 - Theoretical study on buckling of deep water pipeline under external hydrostatic pressure

AU - Wang, Jianhong

AU - Koizumi, Atsushi

PY - 2008

Y1 - 2008

N2 - Generally, the main water pipeline is built through installing steel pipes or iron pipes inside a shield tunnel or NATM tunnel and filling the annular void to form an integrated structure. However, the problem of buckling of inner pipe exists for such a structure because the most of the existing filling technologies fail to produce a tightly fitted liner. When the water pipeline is built deep underground, the separated structure should be adopted in order to ensure the minimum cross section of the tunnel as well as the safety of water pipe. In this study, the buckling of stiffened water pipe used for separated structure is investigated. Firstly, the formulas of general buckling and local buckling are derived with Ritz method, and the methods of the formulas application are given in terms of the critical pressure calculation and the buckling behavior simulation. Secondly, the methods are verified by numerical analysis and existing experiments. Finally, the local buckling design method for separated water pipeline structure is proposed, taking into account of the buckling characters of a practical water pipeline.

AB - Generally, the main water pipeline is built through installing steel pipes or iron pipes inside a shield tunnel or NATM tunnel and filling the annular void to form an integrated structure. However, the problem of buckling of inner pipe exists for such a structure because the most of the existing filling technologies fail to produce a tightly fitted liner. When the water pipeline is built deep underground, the separated structure should be adopted in order to ensure the minimum cross section of the tunnel as well as the safety of water pipe. In this study, the buckling of stiffened water pipe used for separated structure is investigated. Firstly, the formulas of general buckling and local buckling are derived with Ritz method, and the methods of the formulas application are given in terms of the critical pressure calculation and the buckling behavior simulation. Secondly, the methods are verified by numerical analysis and existing experiments. Finally, the local buckling design method for separated water pipeline structure is proposed, taking into account of the buckling characters of a practical water pipeline.

KW - Buckling behavior

KW - Buckling design

KW - Deep underground

KW - Stiffened water pipe

UR - http://www.scopus.com/inward/record.url?scp=77956399464&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77956399464&partnerID=8YFLogxK

U2 - 10.2208/jsceja.64.588

DO - 10.2208/jsceja.64.588

M3 - Article

AN - SCOPUS:77956399464

VL - 64

SP - 588

EP - 602

JO - Doboku Gakkai Ronbunshuu A

JF - Doboku Gakkai Ronbunshuu A

SN - 1880-6023

IS - 3

ER -