Thermal comfort condition of passengers in naturally ventilated train stations

Junta Nakano, Shinichi Tanabe

Research output: Contribution to journalConference article

Abstract

Train is the most frequently used means of transportation in Tokyo. Train stations are gaining attention as commercial complex today, and higher level of comfort is being demanded for the indoor environment. Open structure of the train station and semi-outdoor like environment suggest that the thermal comfort condition is relaxed compared to indoor comfort standards. The objective of this study is to investigate the thermal comfort condition within train stations and to clarify the appropriate target for environmental control. Field surveys were carried out in summer, autumn and winter during July 2004 to August 2006 in four train stations located in urban area of Tokyo. Concourses were not air-conditioned except one station where spot cooling was operated in summer near the ticket gate. Each survey was conducted from 7:00 to 20:00 for 3 to 11 days per season per station for a total of 81 days. The survey consisted of thermal environment measurement and thermal comfort questionnaire. More than 80% of passengers felt thermally comfortable within the range of 19 to 29 °C SET*. However, acceptability zone was found to be 19 to 32 °C SET*, and it is recommended to design naturally ventilated train stations to fulfil this target.

Original languageEnglish
Article number02069
JournalE3S Web of Conferences
Volume111
DOIs
Publication statusPublished - 2019 Aug 13
Event13th REHVA World Congress, CLIMA 2019 - Bucharest, Romania
Duration: 2019 May 262019 May 29

Fingerprint

Thermal comfort
train
Cooling
Air
summer
station
field survey
urban area
autumn
cooling
winter
air

ASJC Scopus subject areas

  • Environmental Science(all)
  • Energy(all)
  • Earth and Planetary Sciences(all)

Cite this

Thermal comfort condition of passengers in naturally ventilated train stations. / Nakano, Junta; Tanabe, Shinichi.

In: E3S Web of Conferences, Vol. 111, 02069, 13.08.2019.

Research output: Contribution to journalConference article

@article{370d5e639d0740268a34bb4a056fd530,
title = "Thermal comfort condition of passengers in naturally ventilated train stations",
abstract = "Train is the most frequently used means of transportation in Tokyo. Train stations are gaining attention as commercial complex today, and higher level of comfort is being demanded for the indoor environment. Open structure of the train station and semi-outdoor like environment suggest that the thermal comfort condition is relaxed compared to indoor comfort standards. The objective of this study is to investigate the thermal comfort condition within train stations and to clarify the appropriate target for environmental control. Field surveys were carried out in summer, autumn and winter during July 2004 to August 2006 in four train stations located in urban area of Tokyo. Concourses were not air-conditioned except one station where spot cooling was operated in summer near the ticket gate. Each survey was conducted from 7:00 to 20:00 for 3 to 11 days per season per station for a total of 81 days. The survey consisted of thermal environment measurement and thermal comfort questionnaire. More than 80{\%} of passengers felt thermally comfortable within the range of 19 to 29 °C SET*. However, acceptability zone was found to be 19 to 32 °C SET*, and it is recommended to design naturally ventilated train stations to fulfil this target.",
author = "Junta Nakano and Shinichi Tanabe",
year = "2019",
month = "8",
day = "13",
doi = "10.1051/e3sconf/201911102069",
language = "English",
volume = "111",
journal = "E3S Web of Conferences",
issn = "2555-0403",
publisher = "EDP Sciences",

}

TY - JOUR

T1 - Thermal comfort condition of passengers in naturally ventilated train stations

AU - Nakano, Junta

AU - Tanabe, Shinichi

PY - 2019/8/13

Y1 - 2019/8/13

N2 - Train is the most frequently used means of transportation in Tokyo. Train stations are gaining attention as commercial complex today, and higher level of comfort is being demanded for the indoor environment. Open structure of the train station and semi-outdoor like environment suggest that the thermal comfort condition is relaxed compared to indoor comfort standards. The objective of this study is to investigate the thermal comfort condition within train stations and to clarify the appropriate target for environmental control. Field surveys were carried out in summer, autumn and winter during July 2004 to August 2006 in four train stations located in urban area of Tokyo. Concourses were not air-conditioned except one station where spot cooling was operated in summer near the ticket gate. Each survey was conducted from 7:00 to 20:00 for 3 to 11 days per season per station for a total of 81 days. The survey consisted of thermal environment measurement and thermal comfort questionnaire. More than 80% of passengers felt thermally comfortable within the range of 19 to 29 °C SET*. However, acceptability zone was found to be 19 to 32 °C SET*, and it is recommended to design naturally ventilated train stations to fulfil this target.

AB - Train is the most frequently used means of transportation in Tokyo. Train stations are gaining attention as commercial complex today, and higher level of comfort is being demanded for the indoor environment. Open structure of the train station and semi-outdoor like environment suggest that the thermal comfort condition is relaxed compared to indoor comfort standards. The objective of this study is to investigate the thermal comfort condition within train stations and to clarify the appropriate target for environmental control. Field surveys were carried out in summer, autumn and winter during July 2004 to August 2006 in four train stations located in urban area of Tokyo. Concourses were not air-conditioned except one station where spot cooling was operated in summer near the ticket gate. Each survey was conducted from 7:00 to 20:00 for 3 to 11 days per season per station for a total of 81 days. The survey consisted of thermal environment measurement and thermal comfort questionnaire. More than 80% of passengers felt thermally comfortable within the range of 19 to 29 °C SET*. However, acceptability zone was found to be 19 to 32 °C SET*, and it is recommended to design naturally ventilated train stations to fulfil this target.

UR - http://www.scopus.com/inward/record.url?scp=85071883515&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85071883515&partnerID=8YFLogxK

U2 - 10.1051/e3sconf/201911102069

DO - 10.1051/e3sconf/201911102069

M3 - Conference article

VL - 111

JO - E3S Web of Conferences

JF - E3S Web of Conferences

SN - 2555-0403

M1 - 02069

ER -