THREE DIMENSIONAL PERMEABILITY MEASUREMENTS.

Nobuo Morita, K. E. Gray

    Research output: Chapter in Book/Report/Conference proceedingChapter

    1 Citation (Scopus)

    Abstract

    Procedures are provided to calculate principal permeabilities and directions from data obtained with a whole core type permeameter which has radial and axial flow measurement capabilities with two openings attached to cylindrical curved surface. The conventional plug method to determine anisotropic permeability was also modified to improve its accuracy; plug number and sample spacing were rigorously designed using error sensitivity numbers. To check the validity of the apparatus, experiments were run using anisotropic Berea sandstone.

    Original languageEnglish
    Title of host publicationSociety of Petroleum Engineers of AIME, (Paper) SPE
    Place of PublicationDallas, Tex
    PublisherSoc of Pet Eng of AIME
    Publication statusPublished - 1980
    EventSoc Pet Eng AIME Pap SPE Presented at the Annu Fall Tech Conf and Exhib, 55th - Dallas, TX, USA
    Duration: 1980 Sep 211980 Sep 24

    Other

    OtherSoc Pet Eng AIME Pap SPE Presented at the Annu Fall Tech Conf and Exhib, 55th
    CityDallas, TX, USA
    Period80/9/2180/9/24

    Fingerprint

    Radial flow
    Axial flow
    Flow measurement
    Sandstone
    Experiments

    ASJC Scopus subject areas

    • Engineering(all)

    Cite this

    Morita, N., & Gray, K. E. (1980). THREE DIMENSIONAL PERMEABILITY MEASUREMENTS. In Society of Petroleum Engineers of AIME, (Paper) SPE Dallas, Tex: Soc of Pet Eng of AIME.

    THREE DIMENSIONAL PERMEABILITY MEASUREMENTS. / Morita, Nobuo; Gray, K. E.

    Society of Petroleum Engineers of AIME, (Paper) SPE. Dallas, Tex : Soc of Pet Eng of AIME, 1980.

    Research output: Chapter in Book/Report/Conference proceedingChapter

    Morita, N & Gray, KE 1980, THREE DIMENSIONAL PERMEABILITY MEASUREMENTS. in Society of Petroleum Engineers of AIME, (Paper) SPE. Soc of Pet Eng of AIME, Dallas, Tex, Soc Pet Eng AIME Pap SPE Presented at the Annu Fall Tech Conf and Exhib, 55th, Dallas, TX, USA, 80/9/21.
    Morita N, Gray KE. THREE DIMENSIONAL PERMEABILITY MEASUREMENTS. In Society of Petroleum Engineers of AIME, (Paper) SPE. Dallas, Tex: Soc of Pet Eng of AIME. 1980
    Morita, Nobuo ; Gray, K. E. / THREE DIMENSIONAL PERMEABILITY MEASUREMENTS. Society of Petroleum Engineers of AIME, (Paper) SPE. Dallas, Tex : Soc of Pet Eng of AIME, 1980.
    @inbook{3be4b581e7474ab59b3da08d20aa88c3,
    title = "THREE DIMENSIONAL PERMEABILITY MEASUREMENTS.",
    abstract = "Procedures are provided to calculate principal permeabilities and directions from data obtained with a whole core type permeameter which has radial and axial flow measurement capabilities with two openings attached to cylindrical curved surface. The conventional plug method to determine anisotropic permeability was also modified to improve its accuracy; plug number and sample spacing were rigorously designed using error sensitivity numbers. To check the validity of the apparatus, experiments were run using anisotropic Berea sandstone.",
    author = "Nobuo Morita and Gray, {K. E.}",
    year = "1980",
    language = "English",
    booktitle = "Society of Petroleum Engineers of AIME, (Paper) SPE",
    publisher = "Soc of Pet Eng of AIME",

    }

    TY - CHAP

    T1 - THREE DIMENSIONAL PERMEABILITY MEASUREMENTS.

    AU - Morita, Nobuo

    AU - Gray, K. E.

    PY - 1980

    Y1 - 1980

    N2 - Procedures are provided to calculate principal permeabilities and directions from data obtained with a whole core type permeameter which has radial and axial flow measurement capabilities with two openings attached to cylindrical curved surface. The conventional plug method to determine anisotropic permeability was also modified to improve its accuracy; plug number and sample spacing were rigorously designed using error sensitivity numbers. To check the validity of the apparatus, experiments were run using anisotropic Berea sandstone.

    AB - Procedures are provided to calculate principal permeabilities and directions from data obtained with a whole core type permeameter which has radial and axial flow measurement capabilities with two openings attached to cylindrical curved surface. The conventional plug method to determine anisotropic permeability was also modified to improve its accuracy; plug number and sample spacing were rigorously designed using error sensitivity numbers. To check the validity of the apparatus, experiments were run using anisotropic Berea sandstone.

    UR - http://www.scopus.com/inward/record.url?scp=0019337157&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=0019337157&partnerID=8YFLogxK

    M3 - Chapter

    BT - Society of Petroleum Engineers of AIME, (Paper) SPE

    PB - Soc of Pet Eng of AIME

    CY - Dallas, Tex

    ER -