Abstract
This paper reports the results of the investigation on the treeing and water treeing resistance of copolymers of ethylene and styrene. The samples are copolymer of ethylene and styrene at 0.42 percent by weight (referred to as S), low-density polyethylene (referred to as P), and laminated layers of the two polymers. As a result, the sample which has S on the needle electrode side has a better treeing resistance than the one which has P on the needle electrode side irrespective of the fact that the test piece is laminated or not. Similar tendency is also seen for the water-treeing resistance.
Original language | English |
---|---|
Pages | 61-64 |
Number of pages | 4 |
Publication status | Published - 1996 Dec 1 |
Externally published | Yes |
Event | Proceedings of Joint Conference: 1996 Asian International Conference on Dielectrics & Electrical Insulation Diagnosis, 96'AICDEI & 4th-JCCEID - Xi'an, China Duration: 1996 Oct 8 → 1996 Oct 11 |
Other
Other | Proceedings of Joint Conference: 1996 Asian International Conference on Dielectrics & Electrical Insulation Diagnosis, 96'AICDEI & 4th-JCCEID |
---|---|
City | Xi'an, China |
Period | 96/10/8 → 96/10/11 |
ASJC Scopus subject areas