Ultrasonic flowmeter with implantable miniature sensors

T. Nakamura, K. Hayashi, Y. Taenaka, Mitsuo Umezu, T. Nakatani, H. Takano

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

An ultrasonic flowmeter incorporated with implantable miniature sensors was developed. Two sets of miniature ultrasonic sensors are attached to the surface of a blood vessel. The outer diameter of the vessel and the blood velocity are measured simultaneously by means of the ultrasonic transit-time technique and the ultrasonic Doppler method, respectively. Instantaneous blood flow is calculated by multiplying the flow velocity by the cross-sectional area calculated from the diameter Stroke volume and cardiac output can also be obtained, when the system is applied to the ascending aorta. After preliminary benchtop tests, acute in vivo studies were carried out to evaluate the accuracy and performance of the system. The blood flow in the descending aortas of dogs and a goat were measured simultaneously by the ultrasonic system and an electromagnetic flowmeter. The correlation coefficient between the data obtained by the two methods was 0·968. The system was applied to measure the blood flow in the ascending aortas of goats which had had heart failures induced and were implanted with left ventricular assist devices.

Original languageEnglish
Pages (from-to)235-242
Number of pages8
JournalMedical & Biological Engineering & Computing
Volume24
Issue number3
DOIs
Publication statusPublished - 1986 May
Externally publishedYes

Fingerprint

Ultrasonic flowmeters
Flowmeters
Ultrasonics
Blood
Sensors
Goats
Left ventricular assist devices
Blood Vessels
Aorta
Ultrasonic sensors
Blood vessels
Heart-Assist Devices
Flow velocity
Electromagnetic Phenomena
Thoracic Aorta
Cardiac Output
Stroke Volume
Heart Failure
Dogs

Keywords

  • Blood flow
  • Cardiac output
  • Implantable miniature sensor
  • Left ventricular assist device
  • Stroke volume
  • Transit-time technique
  • Ultrasonic Doppler flowmetry

ASJC Scopus subject areas

  • Health Information Management
  • Health Informatics
  • Biomedical Engineering
  • Computer Science Applications
  • Computational Theory and Mathematics

Cite this

Ultrasonic flowmeter with implantable miniature sensors. / Nakamura, T.; Hayashi, K.; Taenaka, Y.; Umezu, Mitsuo; Nakatani, T.; Takano, H.

In: Medical & Biological Engineering & Computing, Vol. 24, No. 3, 05.1986, p. 235-242.

Research output: Contribution to journalArticle

Nakamura, T, Hayashi, K, Taenaka, Y, Umezu, M, Nakatani, T & Takano, H 1986, 'Ultrasonic flowmeter with implantable miniature sensors', Medical & Biological Engineering & Computing, vol. 24, no. 3, pp. 235-242. https://doi.org/10.1007/BF02441618
Nakamura, T. ; Hayashi, K. ; Taenaka, Y. ; Umezu, Mitsuo ; Nakatani, T. ; Takano, H. / Ultrasonic flowmeter with implantable miniature sensors. In: Medical & Biological Engineering & Computing. 1986 ; Vol. 24, No. 3. pp. 235-242.
@article{87077b05a1664e0098ebec7fe36c20cc,
title = "Ultrasonic flowmeter with implantable miniature sensors",
abstract = "An ultrasonic flowmeter incorporated with implantable miniature sensors was developed. Two sets of miniature ultrasonic sensors are attached to the surface of a blood vessel. The outer diameter of the vessel and the blood velocity are measured simultaneously by means of the ultrasonic transit-time technique and the ultrasonic Doppler method, respectively. Instantaneous blood flow is calculated by multiplying the flow velocity by the cross-sectional area calculated from the diameter Stroke volume and cardiac output can also be obtained, when the system is applied to the ascending aorta. After preliminary benchtop tests, acute in vivo studies were carried out to evaluate the accuracy and performance of the system. The blood flow in the descending aortas of dogs and a goat were measured simultaneously by the ultrasonic system and an electromagnetic flowmeter. The correlation coefficient between the data obtained by the two methods was 0·968. The system was applied to measure the blood flow in the ascending aortas of goats which had had heart failures induced and were implanted with left ventricular assist devices.",
keywords = "Blood flow, Cardiac output, Implantable miniature sensor, Left ventricular assist device, Stroke volume, Transit-time technique, Ultrasonic Doppler flowmetry",
author = "T. Nakamura and K. Hayashi and Y. Taenaka and Mitsuo Umezu and T. Nakatani and H. Takano",
year = "1986",
month = "5",
doi = "10.1007/BF02441618",
language = "English",
volume = "24",
pages = "235--242",
journal = "Medical and Biological Engineering and Computing",
issn = "0140-0118",
publisher = "Springer Verlag",
number = "3",

}

TY - JOUR

T1 - Ultrasonic flowmeter with implantable miniature sensors

AU - Nakamura, T.

AU - Hayashi, K.

AU - Taenaka, Y.

AU - Umezu, Mitsuo

AU - Nakatani, T.

AU - Takano, H.

PY - 1986/5

Y1 - 1986/5

N2 - An ultrasonic flowmeter incorporated with implantable miniature sensors was developed. Two sets of miniature ultrasonic sensors are attached to the surface of a blood vessel. The outer diameter of the vessel and the blood velocity are measured simultaneously by means of the ultrasonic transit-time technique and the ultrasonic Doppler method, respectively. Instantaneous blood flow is calculated by multiplying the flow velocity by the cross-sectional area calculated from the diameter Stroke volume and cardiac output can also be obtained, when the system is applied to the ascending aorta. After preliminary benchtop tests, acute in vivo studies were carried out to evaluate the accuracy and performance of the system. The blood flow in the descending aortas of dogs and a goat were measured simultaneously by the ultrasonic system and an electromagnetic flowmeter. The correlation coefficient between the data obtained by the two methods was 0·968. The system was applied to measure the blood flow in the ascending aortas of goats which had had heart failures induced and were implanted with left ventricular assist devices.

AB - An ultrasonic flowmeter incorporated with implantable miniature sensors was developed. Two sets of miniature ultrasonic sensors are attached to the surface of a blood vessel. The outer diameter of the vessel and the blood velocity are measured simultaneously by means of the ultrasonic transit-time technique and the ultrasonic Doppler method, respectively. Instantaneous blood flow is calculated by multiplying the flow velocity by the cross-sectional area calculated from the diameter Stroke volume and cardiac output can also be obtained, when the system is applied to the ascending aorta. After preliminary benchtop tests, acute in vivo studies were carried out to evaluate the accuracy and performance of the system. The blood flow in the descending aortas of dogs and a goat were measured simultaneously by the ultrasonic system and an electromagnetic flowmeter. The correlation coefficient between the data obtained by the two methods was 0·968. The system was applied to measure the blood flow in the ascending aortas of goats which had had heart failures induced and were implanted with left ventricular assist devices.

KW - Blood flow

KW - Cardiac output

KW - Implantable miniature sensor

KW - Left ventricular assist device

KW - Stroke volume

KW - Transit-time technique

KW - Ultrasonic Doppler flowmetry

UR - http://www.scopus.com/inward/record.url?scp=0022723984&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022723984&partnerID=8YFLogxK

U2 - 10.1007/BF02441618

DO - 10.1007/BF02441618

M3 - Article

VL - 24

SP - 235

EP - 242

JO - Medical and Biological Engineering and Computing

JF - Medical and Biological Engineering and Computing

SN - 0140-0118

IS - 3

ER -