Abstract
The clay wall, unapproved as a fire-protective material in Building Standard Low, has a problem of the building confirmation. Therefore, clay wall is required to be analyzed on its fire-protective performance. Since clay contains a certain amount of organic substances, it has a probability of combustion and heat releasing. This paper reports the fireprotective ability of wall clay, examining through the cone calorimeter and the gas toxicity, utilized as a means of the approval tests for fireprotective material have been carried out. As a result, the wall clay, even enriched straw, proved that it has a performance of noncombustible matter.
Original language | English |
---|---|
Pages (from-to) | 219-224 |
Number of pages | 6 |
Journal | AIJ Journal of Technology and Design |
Volume | 18 |
Issue number | 38 |
DOIs | |
Publication status | Published - 2012 |
Keywords
- Clay wall
- Fire-safe material
- Gas toxicity
- Gross heating value
- Plastering material
ASJC Scopus subject areas
- Architecture
- Building and Construction