A build-up treatment for thickness gauging of steel plates based on gamma-ray transmission

Y. Shirakawa*

*この研究の対応する著者

研究成果: Conference article査読

19 被引用数 (Scopus)

抄録

A thickness gauging model of steel plates with build-up treatment, which is based on a gamma-ray transmission technique, has been proposed. Its performance has been evaluated by experiments using the real 137Cs thickness gauge equipped at the heavy plate mill in the steel industry. It is shown that the calculated values with the new model are in good agreement with experimental data obtained by the gamma-ray thickness gauge in the thickness range from 0 to 10 cm. Copyright (C) 2000 Elsevier Science Ltd.

本文言語English
ページ(範囲)581-586
ページ数6
ジャーナルApplied Radiation and Isotopes
53
4-5
DOI
出版ステータスPublished - 2000 11月 15
外部発表はい
イベント4th Topical Meeting on the Industrial Radiation and Radioisotope Measurement Applications (IRRMA'99) - Raleigh, NC, USA
継続期間: 1999 10月 31999 10月 7

ASJC Scopus subject areas

  • 放射線

フィンガープリント

「A build-up treatment for thickness gauging of steel plates based on gamma-ray transmission」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル