A new natural ventilation window and its utilization in a detached house

Erika Endo, Koji Hamasaki, Yuka Nakamura, Shinichi Tanabe, Nobuaki Furuya

    研究成果: Conference contribution

    抄録

    Traditional housing units like the ones in Japan, China, and Cambodia are naturally ventilated. Although the windows of contemporary houses are getting smaller to ensure maximum insulation and airtightness, natural ventilation ought to be utilized more for healthy buildings. This is true not only for office buildings but also for housing units. The purpose of this research was to test the operating method and efficiency of a newly developed natural ventilation window for houses. To do this, a field survey was conducted in a detached house with natural ventilation windows. The factors investigated were the thermal environment of the house, the airflow volume through the natural ventilation windows, and window utilization. The following results were obtained: (1) The windows were well opened in the temperature range of 19-25°C. (2) The evaluation of the thermal comfort during naturally ventilation by using an adaptive model showed that the mean indoor operative temperature was coincident with the neutral temperature of the adaptive model.

    元の言語English
    ホスト出版物のタイトル10th International Conference on Healthy Buildings 2012
    ページ1941-1946
    ページ数6
    3
    出版物ステータスPublished - 2012
    イベント10th International Conference on Healthy Buildings 2012 - Brisbane, QLD
    継続期間: 2012 7 82012 7 12

    Other

    Other10th International Conference on Healthy Buildings 2012
    Brisbane, QLD
    期間12/7/812/7/12

    Fingerprint

    Ventilation
    Thermal comfort
    Office buildings
    Temperature
    Insulation

    ASJC Scopus subject areas

    • Civil and Structural Engineering

    これを引用

    Endo, E., Hamasaki, K., Nakamura, Y., Tanabe, S., & Furuya, N. (2012). A new natural ventilation window and its utilization in a detached house. : 10th International Conference on Healthy Buildings 2012 (巻 3, pp. 1941-1946)

    A new natural ventilation window and its utilization in a detached house. / Endo, Erika; Hamasaki, Koji; Nakamura, Yuka; Tanabe, Shinichi; Furuya, Nobuaki.

    10th International Conference on Healthy Buildings 2012. 巻 3 2012. p. 1941-1946.

    研究成果: Conference contribution

    Endo, E, Hamasaki, K, Nakamura, Y, Tanabe, S & Furuya, N 2012, A new natural ventilation window and its utilization in a detached house. : 10th International Conference on Healthy Buildings 2012. 巻. 3, pp. 1941-1946, 10th International Conference on Healthy Buildings 2012, Brisbane, QLD, 12/7/8.
    Endo E, Hamasaki K, Nakamura Y, Tanabe S, Furuya N. A new natural ventilation window and its utilization in a detached house. : 10th International Conference on Healthy Buildings 2012. 巻 3. 2012. p. 1941-1946
    Endo, Erika ; Hamasaki, Koji ; Nakamura, Yuka ; Tanabe, Shinichi ; Furuya, Nobuaki. / A new natural ventilation window and its utilization in a detached house. 10th International Conference on Healthy Buildings 2012. 巻 3 2012. pp. 1941-1946
    @inproceedings{9f1b643b1b234929b09f060e67b4524b,
    title = "A new natural ventilation window and its utilization in a detached house",
    abstract = "Traditional housing units like the ones in Japan, China, and Cambodia are naturally ventilated. Although the windows of contemporary houses are getting smaller to ensure maximum insulation and airtightness, natural ventilation ought to be utilized more for healthy buildings. This is true not only for office buildings but also for housing units. The purpose of this research was to test the operating method and efficiency of a newly developed natural ventilation window for houses. To do this, a field survey was conducted in a detached house with natural ventilation windows. The factors investigated were the thermal environment of the house, the airflow volume through the natural ventilation windows, and window utilization. The following results were obtained: (1) The windows were well opened in the temperature range of 19-25°C. (2) The evaluation of the thermal comfort during naturally ventilation by using an adaptive model showed that the mean indoor operative temperature was coincident with the neutral temperature of the adaptive model.",
    keywords = "(Natural Ventilation, Adaptive Model), Detached House, Thermal Comfort, Window Opening",
    author = "Erika Endo and Koji Hamasaki and Yuka Nakamura and Shinichi Tanabe and Nobuaki Furuya",
    year = "2012",
    language = "English",
    isbn = "9781627480758",
    volume = "3",
    pages = "1941--1946",
    booktitle = "10th International Conference on Healthy Buildings 2012",

    }

    TY - GEN

    T1 - A new natural ventilation window and its utilization in a detached house

    AU - Endo, Erika

    AU - Hamasaki, Koji

    AU - Nakamura, Yuka

    AU - Tanabe, Shinichi

    AU - Furuya, Nobuaki

    PY - 2012

    Y1 - 2012

    N2 - Traditional housing units like the ones in Japan, China, and Cambodia are naturally ventilated. Although the windows of contemporary houses are getting smaller to ensure maximum insulation and airtightness, natural ventilation ought to be utilized more for healthy buildings. This is true not only for office buildings but also for housing units. The purpose of this research was to test the operating method and efficiency of a newly developed natural ventilation window for houses. To do this, a field survey was conducted in a detached house with natural ventilation windows. The factors investigated were the thermal environment of the house, the airflow volume through the natural ventilation windows, and window utilization. The following results were obtained: (1) The windows were well opened in the temperature range of 19-25°C. (2) The evaluation of the thermal comfort during naturally ventilation by using an adaptive model showed that the mean indoor operative temperature was coincident with the neutral temperature of the adaptive model.

    AB - Traditional housing units like the ones in Japan, China, and Cambodia are naturally ventilated. Although the windows of contemporary houses are getting smaller to ensure maximum insulation and airtightness, natural ventilation ought to be utilized more for healthy buildings. This is true not only for office buildings but also for housing units. The purpose of this research was to test the operating method and efficiency of a newly developed natural ventilation window for houses. To do this, a field survey was conducted in a detached house with natural ventilation windows. The factors investigated were the thermal environment of the house, the airflow volume through the natural ventilation windows, and window utilization. The following results were obtained: (1) The windows were well opened in the temperature range of 19-25°C. (2) The evaluation of the thermal comfort during naturally ventilation by using an adaptive model showed that the mean indoor operative temperature was coincident with the neutral temperature of the adaptive model.

    KW - (Natural Ventilation

    KW - Adaptive Model)

    KW - Detached House

    KW - Thermal Comfort

    KW - Window Opening

    UR - http://www.scopus.com/inward/record.url?scp=84883436569&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84883436569&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:84883436569

    SN - 9781627480758

    VL - 3

    SP - 1941

    EP - 1946

    BT - 10th International Conference on Healthy Buildings 2012

    ER -