A study for reduction of radiation pressure noise in gravitational wave detectors

S. Sakata, V. Leonhardt, S. Kawamura, K. Numata, O. Miyakawa, S. Sato, A. Nishizawa, T. Yamazaki, Mitsuhiro Fukushima, A. Furusawa, A. Sugamoto

研究成果: Article査読

4 被引用数 (Scopus)

抄録

We describe an experimental conceptual design for observation and reduction of radiation pressure noise. The radiation pressure noise is increased in a high finesse cavity with a small mass mirror. In our experiment a Fabry-Perot Michelson interferometer with a homodyne detection scheme will be built with Fabry-Perot cavities of finesse of 10000 containing suspended mirrors of 23 mg. To observe the radiation pressure noise, the goal sensitivity is set to 1×10-17 [m/ Hz] at 1 kHz. Then the radiation pressure noise is reduced by adjusting the homodyne phase. To achieve the sensitivity, the other noise sources such as thermal noises, seismic noise and laser frequency noise should be suppressed below 1×10-18 [m/ Hz] at 1kHz. The whole interferometer is suspended as a double pendulum on double-layer stacks. As a preliminary setup, a Fabry-Perot cavity of finesse of 800 with a suspended mirror of 100 mg was locked. The current best sensitivity is 1×10 -15 [m/ Hz] at 1 kHz.

本文言語English
論文番号012020
ジャーナルJournal of Physics: Conference Series
122
DOI
出版ステータスPublished - 2008
外部発表はい

ASJC Scopus subject areas

  • Physics and Astronomy(all)

フィンガープリント 「A study for reduction of radiation pressure noise in gravitational wave detectors」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。