A study of modeling of EMTP analysis for indoor distribution line

Toshiya Abe, Toshihiro Tsuboi, Yoshiki Sakamoto, Teru Miyazaki, Shigemitsu Okabe

研究成果: Article

抄録

Damage to home electric appliances due to lightning surges has recently become more common. The installation of SPDs (surge protective devices) in interior wiring is a countermeasure against damage and is also becoming more widespread after amendment of the regulation on indoor wires in 2005. Past study showed an effective method in which the earth line of the SPD is connected with that of home appliances and is grounded at one place in the home. However, because the methods of installing the distribution line in homes vary, it is difficult to estimate the effect of SPDs in every home, and high-precision analysis by EMTP for interior wiring and SPD in the home is required. In this study, experiments were conducted with interior wiring and varistors, which constitute SPDs, and this paper reports the results of those experiments and of EMTP analytical models.

元の言語English
ページ(範囲)24-33
ページ数10
ジャーナルElectrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi)
175
発行部数4
DOI
出版物ステータスPublished - 2011 6 1
外部発表Yes

Fingerprint

Electric wiring
Electric appliances
Varistors
Domestic appliances
Lightning
Analytical models
Earth (planet)
Experiments
Wire

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering

これを引用

A study of modeling of EMTP analysis for indoor distribution line. / Abe, Toshiya; Tsuboi, Toshihiro; Sakamoto, Yoshiki; Miyazaki, Teru; Okabe, Shigemitsu.

:: Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi), 巻 175, 番号 4, 01.06.2011, p. 24-33.

研究成果: Article

Abe, Toshiya ; Tsuboi, Toshihiro ; Sakamoto, Yoshiki ; Miyazaki, Teru ; Okabe, Shigemitsu. / A study of modeling of EMTP analysis for indoor distribution line. :: Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi). 2011 ; 巻 175, 番号 4. pp. 24-33.
@article{1d0e9bcb2f1c4e86843d30db1658e2fe,
title = "A study of modeling of EMTP analysis for indoor distribution line",
abstract = "Damage to home electric appliances due to lightning surges has recently become more common. The installation of SPDs (surge protective devices) in interior wiring is a countermeasure against damage and is also becoming more widespread after amendment of the regulation on indoor wires in 2005. Past study showed an effective method in which the earth line of the SPD is connected with that of home appliances and is grounded at one place in the home. However, because the methods of installing the distribution line in homes vary, it is difficult to estimate the effect of SPDs in every home, and high-precision analysis by EMTP for interior wiring and SPD in the home is required. In this study, experiments were conducted with interior wiring and varistors, which constitute SPDs, and this paper reports the results of those experiments and of EMTP analytical models.",
keywords = "EMTP analysis model, indoor distribution line, lightning protection, lightning surge, surge protective device, varistor",
author = "Toshiya Abe and Toshihiro Tsuboi and Yoshiki Sakamoto and Teru Miyazaki and Shigemitsu Okabe",
year = "2011",
month = "6",
day = "1",
doi = "10.1002/eej.21062",
language = "English",
volume = "175",
pages = "24--33",
journal = "Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi)",
issn = "0424-7760",
publisher = "John Wiley and Sons Inc.",
number = "4",

}

TY - JOUR

T1 - A study of modeling of EMTP analysis for indoor distribution line

AU - Abe, Toshiya

AU - Tsuboi, Toshihiro

AU - Sakamoto, Yoshiki

AU - Miyazaki, Teru

AU - Okabe, Shigemitsu

PY - 2011/6/1

Y1 - 2011/6/1

N2 - Damage to home electric appliances due to lightning surges has recently become more common. The installation of SPDs (surge protective devices) in interior wiring is a countermeasure against damage and is also becoming more widespread after amendment of the regulation on indoor wires in 2005. Past study showed an effective method in which the earth line of the SPD is connected with that of home appliances and is grounded at one place in the home. However, because the methods of installing the distribution line in homes vary, it is difficult to estimate the effect of SPDs in every home, and high-precision analysis by EMTP for interior wiring and SPD in the home is required. In this study, experiments were conducted with interior wiring and varistors, which constitute SPDs, and this paper reports the results of those experiments and of EMTP analytical models.

AB - Damage to home electric appliances due to lightning surges has recently become more common. The installation of SPDs (surge protective devices) in interior wiring is a countermeasure against damage and is also becoming more widespread after amendment of the regulation on indoor wires in 2005. Past study showed an effective method in which the earth line of the SPD is connected with that of home appliances and is grounded at one place in the home. However, because the methods of installing the distribution line in homes vary, it is difficult to estimate the effect of SPDs in every home, and high-precision analysis by EMTP for interior wiring and SPD in the home is required. In this study, experiments were conducted with interior wiring and varistors, which constitute SPDs, and this paper reports the results of those experiments and of EMTP analytical models.

KW - EMTP analysis model

KW - indoor distribution line

KW - lightning protection

KW - lightning surge

KW - surge protective device

KW - varistor

UR - http://www.scopus.com/inward/record.url?scp=79954504257&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79954504257&partnerID=8YFLogxK

U2 - 10.1002/eej.21062

DO - 10.1002/eej.21062

M3 - Article

AN - SCOPUS:79954504257

VL - 175

SP - 24

EP - 33

JO - Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi)

JF - Electrical Engineering in Japan (English translation of Denki Gakkai Ronbunshi)

SN - 0424-7760

IS - 4

ER -