A study of modeling of EMTP-analysis for indoor distribution line

Toshiya Abe, Toshihiro Tsuboi, Yoshiki Sakamoto, Teru Miyazaki, Shigemitsu Okabe

研究成果: Article

3 引用 (Scopus)

抜粋

The number of damages of home electric appliances due to lightning surges have recently increased. Instllation of SPDs (Surge Protective Device) in interior wireing is one of countermeasures against the damages and is also spreading after an amendment of the regulation on indoor wires in 2005. Past study showed effective mthod, the earth line of SPD is connected with that of home appliances and is grounded at one place at home. However, because the institution ways of the distribution line at each home are various, it is difficult to estimate the effect of SPD at every home, and the high-precision analysis by EMTP for interior wiring and SPD at home is required. In this study, experiments were conducted with interior wiring and varisters which constitues SPD, and this paper report the results by those experiments and EMTP analytical models.

元の言語English
ページ(範囲)1481-1489+8
ジャーナルIEEJ Transactions on Power and Energy
128
発行部数12
DOI
出版物ステータスPublished - 2008 12 1
外部発表Yes

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering