A trial thermal rectifier

Wataru Kobayashi, Y. Teraoka, I. Terasaki

    研究成果: Article

    8 引用 (Scopus)

    抜粋

    We have prepared a trial oxide thermal rectifier made of two cobalt oxides with different thermal conductivities based on a theoretical design. We created an experimental system to measure the thermal rectification and found that the rectifying coefficient defined by the ratio of heat current in a forward direction to that in the opposite direction was 1.43. We verified the thermal rectification by analyzing it quantitatively.

    元の言語English
    ページ(範囲)1488-1492
    ページ数5
    ジャーナルJournal of Electronic Materials
    39
    発行部数9
    DOI
    出版物ステータスPublished - 2010 9

      フィンガープリント

    ASJC Scopus subject areas

    • Electrical and Electronic Engineering
    • Electronic, Optical and Magnetic Materials
    • Condensed Matter Physics
    • Materials Chemistry

    これを引用

    Kobayashi, W., Teraoka, Y., & Terasaki, I. (2010). A trial thermal rectifier. Journal of Electronic Materials, 39(9), 1488-1492. https://doi.org/10.1007/s11664-010-1302-5