An ultrahigh spatial resolution radiation-imaging detector using 0.1 mm × 0.1 mm pixelated GAGG plate combined with 1 mm channel size Si-PM array

Seiichi Yamamoto, Jun Kataoka, Kei Kamada, Akira Yoshikawa

    研究成果: Article

    抄録

    Spatial resolution of a pixelated scintillator-based radiation-imaging detector is sometimes limited by the pixel size of the scintillators. We developed a small-size pixelated GAGG scintillator using a dicing method and combined it with a small channel-size Si-PM array for the development of an ultrahigh resolution radiation-imaging detector. The developed pixelated GAGG scintillator had a pixel size of 0.1 mm × 0.1 mm arranged in 0.15-mm separations. It was combined with a Si-PM array made of 1 mm × 1 mm channels to form a radiation-imaging detector. With the developed radiation imaging detectors, the 0.1 mm × 0.1 mm pixels could be resolved for Am-241 alpha particles (5.5 MeV). The spatial resolutions of this imaging detector were better than 0.31-mm FWHM for Am-241 alpha particles and Ca-45 (maximum energy: 0.257 MeV) beta particles. The spatial resolutions for Am-241 gamma photons (60 keV) and Cs-137 X-ray (∼32 keV) were better than 0.6-mm FWHM. Separation of the images of alpha particles and gamma photons was possible using the scintillation decay time difference of GAGG between alpha particles and gamma photons. The developed ultrahigh spatial resolution pixelated GAGG radiation-imaging detector is promising for the imaging of alpha particles, beta particles, low-energy gamma photons and X-ray.

    元の言語English
    ページ(範囲)125-133
    ページ数9
    ジャーナルNuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
    919
    DOI
    出版物ステータスPublished - 2019 3 1

    Fingerprint

    Alpha particles
    spatial resolution
    alpha particles
    Detectors
    Imaging techniques
    Radiation
    scintillation counters
    detectors
    Phosphors
    radiation
    Photons
    beta particles
    pixels
    photons
    Pixels
    Full width at half maximum
    X rays
    Scintillation
    scintillation
    x rays

    Keywords

      ASJC Scopus subject areas

      • Nuclear and High Energy Physics
      • Instrumentation

      これを引用

      @article{bdac2763e57e4bbca5ee8c4caca07fa5,
      title = "An ultrahigh spatial resolution radiation-imaging detector using 0.1 mm × 0.1 mm pixelated GAGG plate combined with 1 mm channel size Si-PM array",
      abstract = "Spatial resolution of a pixelated scintillator-based radiation-imaging detector is sometimes limited by the pixel size of the scintillators. We developed a small-size pixelated GAGG scintillator using a dicing method and combined it with a small channel-size Si-PM array for the development of an ultrahigh resolution radiation-imaging detector. The developed pixelated GAGG scintillator had a pixel size of 0.1 mm × 0.1 mm arranged in 0.15-mm separations. It was combined with a Si-PM array made of 1 mm × 1 mm channels to form a radiation-imaging detector. With the developed radiation imaging detectors, the 0.1 mm × 0.1 mm pixels could be resolved for Am-241 alpha particles (5.5 MeV). The spatial resolutions of this imaging detector were better than 0.31-mm FWHM for Am-241 alpha particles and Ca-45 (maximum energy: 0.257 MeV) beta particles. The spatial resolutions for Am-241 gamma photons (60 keV) and Cs-137 X-ray (∼32 keV) were better than 0.6-mm FWHM. Separation of the images of alpha particles and gamma photons was possible using the scintillation decay time difference of GAGG between alpha particles and gamma photons. The developed ultrahigh spatial resolution pixelated GAGG radiation-imaging detector is promising for the imaging of alpha particles, beta particles, low-energy gamma photons and X-ray.",
      keywords = "GAGG, Pixelated, Pulse-shape discrimination, Si-PM array, Ultrahigh spatial resolution",
      author = "Seiichi Yamamoto and Jun Kataoka and Kei Kamada and Akira Yoshikawa",
      year = "2019",
      month = "3",
      day = "1",
      doi = "10.1016/j.nima.2018.12.002",
      language = "English",
      volume = "919",
      pages = "125--133",
      journal = "Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment",
      issn = "0168-9002",
      publisher = "Elsevier",

      }

      TY - JOUR

      T1 - An ultrahigh spatial resolution radiation-imaging detector using 0.1 mm × 0.1 mm pixelated GAGG plate combined with 1 mm channel size Si-PM array

      AU - Yamamoto, Seiichi

      AU - Kataoka, Jun

      AU - Kamada, Kei

      AU - Yoshikawa, Akira

      PY - 2019/3/1

      Y1 - 2019/3/1

      N2 - Spatial resolution of a pixelated scintillator-based radiation-imaging detector is sometimes limited by the pixel size of the scintillators. We developed a small-size pixelated GAGG scintillator using a dicing method and combined it with a small channel-size Si-PM array for the development of an ultrahigh resolution radiation-imaging detector. The developed pixelated GAGG scintillator had a pixel size of 0.1 mm × 0.1 mm arranged in 0.15-mm separations. It was combined with a Si-PM array made of 1 mm × 1 mm channels to form a radiation-imaging detector. With the developed radiation imaging detectors, the 0.1 mm × 0.1 mm pixels could be resolved for Am-241 alpha particles (5.5 MeV). The spatial resolutions of this imaging detector were better than 0.31-mm FWHM for Am-241 alpha particles and Ca-45 (maximum energy: 0.257 MeV) beta particles. The spatial resolutions for Am-241 gamma photons (60 keV) and Cs-137 X-ray (∼32 keV) were better than 0.6-mm FWHM. Separation of the images of alpha particles and gamma photons was possible using the scintillation decay time difference of GAGG between alpha particles and gamma photons. The developed ultrahigh spatial resolution pixelated GAGG radiation-imaging detector is promising for the imaging of alpha particles, beta particles, low-energy gamma photons and X-ray.

      AB - Spatial resolution of a pixelated scintillator-based radiation-imaging detector is sometimes limited by the pixel size of the scintillators. We developed a small-size pixelated GAGG scintillator using a dicing method and combined it with a small channel-size Si-PM array for the development of an ultrahigh resolution radiation-imaging detector. The developed pixelated GAGG scintillator had a pixel size of 0.1 mm × 0.1 mm arranged in 0.15-mm separations. It was combined with a Si-PM array made of 1 mm × 1 mm channels to form a radiation-imaging detector. With the developed radiation imaging detectors, the 0.1 mm × 0.1 mm pixels could be resolved for Am-241 alpha particles (5.5 MeV). The spatial resolutions of this imaging detector were better than 0.31-mm FWHM for Am-241 alpha particles and Ca-45 (maximum energy: 0.257 MeV) beta particles. The spatial resolutions for Am-241 gamma photons (60 keV) and Cs-137 X-ray (∼32 keV) were better than 0.6-mm FWHM. Separation of the images of alpha particles and gamma photons was possible using the scintillation decay time difference of GAGG between alpha particles and gamma photons. The developed ultrahigh spatial resolution pixelated GAGG radiation-imaging detector is promising for the imaging of alpha particles, beta particles, low-energy gamma photons and X-ray.

      KW - GAGG

      KW - Pixelated

      KW - Pulse-shape discrimination

      KW - Si-PM array

      KW - Ultrahigh spatial resolution

      UR - http://www.scopus.com/inward/record.url?scp=85059162811&partnerID=8YFLogxK

      UR - http://www.scopus.com/inward/citedby.url?scp=85059162811&partnerID=8YFLogxK

      U2 - 10.1016/j.nima.2018.12.002

      DO - 10.1016/j.nima.2018.12.002

      M3 - Article

      VL - 919

      SP - 125

      EP - 133

      JO - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

      JF - Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

      SN - 0168-9002

      ER -