TY - JOUR
T1 - Cascade refrigeration system with inverse Brayton cycle on the cold side
AU - Giannetti, Niccolò
AU - Milazzo, Adriano
AU - Rocchetti, Andrea
AU - Saito, Kiyoshi
N1 - Funding Information:
This work has been supported by MIUR of Italy within the framework of PRIN2015 project «Clean Heating and Cooling Technologies for an Energy Efficient Smart Grid».
Publisher Copyright:
© 2017 Elsevier Ltd
PY - 2017/12/25
Y1 - 2017/12/25
N2 - Low temperature refrigeration of cold stores poses some specific issues: single stage, vapour compression cycles have modest COP at low evaporation temperature; cold evaporator surfaces require de-frosting and a fan for air circulation; a part of the refrigeration load may be delivered at intermediate temperature levels, e.g. for the cold store loading dock. Cascade system may improve the COP and add flexibility on the temperature levels and working fluids, but the problems related to the cold evaporator surface remain unsolved. The refrigeration system presented herein features a cascade configuration combining a vapour compression cycle and an inverse Brayton cycle. Both cycles use “natural” fluids, complying with strictest regulations. The top cycle uses Ammonia in order to increase efficiency, while the bottom cycle uses air, which directly circulates in the cold space and hence eliminates the cold heat exchanger. A detailed thermodynamic analysis allows a complete screening of the relevant design parameters for an overall system optimization. The results show that, notwithstanding the intrinsic gap of efficiency suffered by the Brayton cycle, the proposed system features an acceptable global performance and widens the implementation field of this technology. This system configuration shows a COP 50% higher than the corresponding simple Brayton cycle at temperatures of the refrigerated storage of −50 °C.
AB - Low temperature refrigeration of cold stores poses some specific issues: single stage, vapour compression cycles have modest COP at low evaporation temperature; cold evaporator surfaces require de-frosting and a fan for air circulation; a part of the refrigeration load may be delivered at intermediate temperature levels, e.g. for the cold store loading dock. Cascade system may improve the COP and add flexibility on the temperature levels and working fluids, but the problems related to the cold evaporator surface remain unsolved. The refrigeration system presented herein features a cascade configuration combining a vapour compression cycle and an inverse Brayton cycle. Both cycles use “natural” fluids, complying with strictest regulations. The top cycle uses Ammonia in order to increase efficiency, while the bottom cycle uses air, which directly circulates in the cold space and hence eliminates the cold heat exchanger. A detailed thermodynamic analysis allows a complete screening of the relevant design parameters for an overall system optimization. The results show that, notwithstanding the intrinsic gap of efficiency suffered by the Brayton cycle, the proposed system features an acceptable global performance and widens the implementation field of this technology. This system configuration shows a COP 50% higher than the corresponding simple Brayton cycle at temperatures of the refrigerated storage of −50 °C.
KW - Cascade system
KW - Cold-store refrigeration
KW - Inverse Brayton cycle
KW - Performance analysis
UR - http://www.scopus.com/inward/record.url?scp=85028373130&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85028373130&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2017.08.067
DO - 10.1016/j.applthermaleng.2017.08.067
M3 - Article
AN - SCOPUS:85028373130
SN - 1359-4311
VL - 127
SP - 986
EP - 995
JO - Journal of Heat Recovery Systems
JF - Journal of Heat Recovery Systems
ER -