Characteristics of air-conditioning heat load of a large space building under constant PMV condition -comparison of occupied zone air-conditioning system and spot air-conditioning system

Noboru Sakuragi, Yasuyuki Shiraishi, Shin Ichi Tanabe, Ken Ichi Kimura

研究成果: Conference contribution

抜粋

We evaluated the air-conditioning heat load of spot air-conditioning system in a large space building like a factory by a coupled simulation of convention, radiation, moisture transportation and air-conditioning system control under constant PMV condition. The energy saving performance of this system was evaluated in comparison with the results of occupied zone air-conditioning system. The following results were obtained: 1) Indoor surface temperature was higher and thermal transmission load was lower in spot air-conditioning. 2) PMV values at eight evaluation points were almost the same in spot air-conditioning. 3) Sensible heat load decreased one third by making the set value of PMV lower from 2.0 to 0.5 in occupied zone air-conditioning, and one fourth in spot airconditioning. 4) Sensible heat load decreased two third by making the air temperature at supply opening lower from 20oC to 12oC in occupied zone air-conditioning, and three fifth in spot airconditioning.

元の言語English
ホスト出版物のタイトル22nd International Conference, PLEA 2005
ホスト出版物のサブタイトルPassive and Low Energy Architecture - Environmental Sustainability: The Challenge of Awareness in Developing Societies, Proceedings
ページ803-808
ページ数6
出版物ステータスPublished - 2005 12 1
イベント22nd International Conference on Passive and Low Energy Architecture, PLEA 2005 - Beirut, Lebanon
継続期間: 2005 11 132005 11 16

出版物シリーズ

名前22nd International Conference, PLEA 2005: Passive and Low Energy Architecture - Environmental Sustainability: The Challenge of Awareness in Developing Societies, Proceedings
2

Conference

Conference22nd International Conference on Passive and Low Energy Architecture, PLEA 2005
Lebanon
Beirut
期間05/11/1305/11/16

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Renewable Energy, Sustainability and the Environment

フィンガープリント Characteristics of air-conditioning heat load of a large space building under constant PMV condition -comparison of occupied zone air-conditioning system and spot air-conditioning system' の研究トピックを掘り下げます。これらはともに一意のフィンガープリントを構成します。

  • これを引用

    Sakuragi, N., Shiraishi, Y., Tanabe, S. I., & Kimura, K. I. (2005). Characteristics of air-conditioning heat load of a large space building under constant PMV condition -comparison of occupied zone air-conditioning system and spot air-conditioning system. : 22nd International Conference, PLEA 2005: Passive and Low Energy Architecture - Environmental Sustainability: The Challenge of Awareness in Developing Societies, Proceedings (pp. 803-808). (22nd International Conference, PLEA 2005: Passive and Low Energy Architecture - Environmental Sustainability: The Challenge of Awareness in Developing Societies, Proceedings; 巻数 2).