Characteristics of piezoelectric lead zirconate titanate fourteen-layered detector bombarded with high-energy xenon beam

Seiji Takechi, Takashi Miyachi, Masayuki Fujii, Nobuyuki Hasebe, Kunishiro Mori, Hiromi Shibata, Takeshi Murakami, Yukio Uchihori, Nagaya Okada

    研究成果: Article

    10 引用 (Scopus)

    抄録

    A radiation detector composed of fourteen lead zirconate titanate (PZT) disks was studied by directly irradiating it using a 400 MeV/n xenon beam while changing the beam intensity and beam pulse duration. The results obtained indicated that the sensitivity of the detector per xenon ion was explicitly dependent on the beam pulse duration. Comparing the sensitivity among PZT detectors with one, fourteen and one hundred layers, it was also found that the sensitivity of the fourteen-layered detector was highest under the experimental conditions.

    元の言語English
    ページ(範囲)365-368
    ページ数4
    ジャーナルSensors and Actuators, A: Physical
    147
    発行部数2
    DOI
    出版物ステータスPublished - 2008 10 3

    Fingerprint

    Xenon
    xenon
    Lead
    Detectors
    detectors
    sensitivity
    Radiation detectors
    pulse duration
    energy
    radiation detectors
    Ions
    lead titanate zirconate
    ions

    ASJC Scopus subject areas

    • Electrical and Electronic Engineering
    • Mechanical Engineering
    • Instrumentation

    これを引用

    Characteristics of piezoelectric lead zirconate titanate fourteen-layered detector bombarded with high-energy xenon beam. / Takechi, Seiji; Miyachi, Takashi; Fujii, Masayuki; Hasebe, Nobuyuki; Mori, Kunishiro; Shibata, Hiromi; Murakami, Takeshi; Uchihori, Yukio; Okada, Nagaya.

    :: Sensors and Actuators, A: Physical, 巻 147, 番号 2, 03.10.2008, p. 365-368.

    研究成果: Article

    Takechi, S, Miyachi, T, Fujii, M, Hasebe, N, Mori, K, Shibata, H, Murakami, T, Uchihori, Y & Okada, N 2008, 'Characteristics of piezoelectric lead zirconate titanate fourteen-layered detector bombarded with high-energy xenon beam', Sensors and Actuators, A: Physical, 巻. 147, 番号 2, pp. 365-368. https://doi.org/10.1016/j.sna.2008.06.002
    Takechi, Seiji ; Miyachi, Takashi ; Fujii, Masayuki ; Hasebe, Nobuyuki ; Mori, Kunishiro ; Shibata, Hiromi ; Murakami, Takeshi ; Uchihori, Yukio ; Okada, Nagaya. / Characteristics of piezoelectric lead zirconate titanate fourteen-layered detector bombarded with high-energy xenon beam. :: Sensors and Actuators, A: Physical. 2008 ; 巻 147, 番号 2. pp. 365-368.
    @article{daaedd7d6f134066abed9cfa97220f90,
    title = "Characteristics of piezoelectric lead zirconate titanate fourteen-layered detector bombarded with high-energy xenon beam",
    abstract = "A radiation detector composed of fourteen lead zirconate titanate (PZT) disks was studied by directly irradiating it using a 400 MeV/n xenon beam while changing the beam intensity and beam pulse duration. The results obtained indicated that the sensitivity of the detector per xenon ion was explicitly dependent on the beam pulse duration. Comparing the sensitivity among PZT detectors with one, fourteen and one hundred layers, it was also found that the sensitivity of the fourteen-layered detector was highest under the experimental conditions.",
    keywords = "Acoustic radiation detector, Lead zirconate titanate (PZT), Multilayer, Piezoelectricity, Radiology",
    author = "Seiji Takechi and Takashi Miyachi and Masayuki Fujii and Nobuyuki Hasebe and Kunishiro Mori and Hiromi Shibata and Takeshi Murakami and Yukio Uchihori and Nagaya Okada",
    year = "2008",
    month = "10",
    day = "3",
    doi = "10.1016/j.sna.2008.06.002",
    language = "English",
    volume = "147",
    pages = "365--368",
    journal = "Sensors and Actuators, A: Physical",
    issn = "0924-4247",
    publisher = "Elsevier",
    number = "2",

    }

    TY - JOUR

    T1 - Characteristics of piezoelectric lead zirconate titanate fourteen-layered detector bombarded with high-energy xenon beam

    AU - Takechi, Seiji

    AU - Miyachi, Takashi

    AU - Fujii, Masayuki

    AU - Hasebe, Nobuyuki

    AU - Mori, Kunishiro

    AU - Shibata, Hiromi

    AU - Murakami, Takeshi

    AU - Uchihori, Yukio

    AU - Okada, Nagaya

    PY - 2008/10/3

    Y1 - 2008/10/3

    N2 - A radiation detector composed of fourteen lead zirconate titanate (PZT) disks was studied by directly irradiating it using a 400 MeV/n xenon beam while changing the beam intensity and beam pulse duration. The results obtained indicated that the sensitivity of the detector per xenon ion was explicitly dependent on the beam pulse duration. Comparing the sensitivity among PZT detectors with one, fourteen and one hundred layers, it was also found that the sensitivity of the fourteen-layered detector was highest under the experimental conditions.

    AB - A radiation detector composed of fourteen lead zirconate titanate (PZT) disks was studied by directly irradiating it using a 400 MeV/n xenon beam while changing the beam intensity and beam pulse duration. The results obtained indicated that the sensitivity of the detector per xenon ion was explicitly dependent on the beam pulse duration. Comparing the sensitivity among PZT detectors with one, fourteen and one hundred layers, it was also found that the sensitivity of the fourteen-layered detector was highest under the experimental conditions.

    KW - Acoustic radiation detector

    KW - Lead zirconate titanate (PZT)

    KW - Multilayer

    KW - Piezoelectricity

    KW - Radiology

    UR - http://www.scopus.com/inward/record.url?scp=49649124337&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=49649124337&partnerID=8YFLogxK

    U2 - 10.1016/j.sna.2008.06.002

    DO - 10.1016/j.sna.2008.06.002

    M3 - Article

    AN - SCOPUS:49649124337

    VL - 147

    SP - 365

    EP - 368

    JO - Sensors and Actuators, A: Physical

    JF - Sensors and Actuators, A: Physical

    SN - 0924-4247

    IS - 2

    ER -