TY - JOUR
T1 - Comfort limits for asymmetric thermal radiation
AU - Fanger, P. O.
AU - Ipsen, B. M.
AU - Langkilde, G.
AU - Olessen, B. W.
AU - Christensen, N. K.
AU - Tanabe, S.
PY - 1985/8
Y1 - 1985/8
N2 - Groups of 32 and 16 subjects of both sexes were exposed in an environmental chamber to radiant asymmetry caused by a cool wall, a warm wall, and a cool ceiling. Each subject was tested individually while seated and clothed at 0.6 clo. During each 3.5-hour experiment the subject was exposed to six radiant temperature asymmetries. He was asked whether and where he experienced any local cool or warm sensation, and whether it was felt to be uncomfortable. During the entire experiment he was kept thermally neutral by changing the air temperature according to his wishes. For cool walls, warm walls, and cool ceilings curves have been established showing the percentage of dissatisfied subjects as a function of the radiant asymmetry. Radiant asymmetry at a warm wall caused less discomfort than a cool wall. A cool ceiling caused less discomfort than a warm ceiling. Accepting that 5% of the subjects may feel uncomfortable. a radiant temperature asymmetry of 10°C is allowable at a cool wall, 23°C at a warm wall, and 14°C under a cool ceiling. A previous study showed that 4°C is allowable under a warm ceiling. Radiant asymmetry had no significant impact on the operative temperatures preferred by the subjects. No significant differences were observed between the responses of men and women exposed to radiant asymmetry.
AB - Groups of 32 and 16 subjects of both sexes were exposed in an environmental chamber to radiant asymmetry caused by a cool wall, a warm wall, and a cool ceiling. Each subject was tested individually while seated and clothed at 0.6 clo. During each 3.5-hour experiment the subject was exposed to six radiant temperature asymmetries. He was asked whether and where he experienced any local cool or warm sensation, and whether it was felt to be uncomfortable. During the entire experiment he was kept thermally neutral by changing the air temperature according to his wishes. For cool walls, warm walls, and cool ceilings curves have been established showing the percentage of dissatisfied subjects as a function of the radiant asymmetry. Radiant asymmetry at a warm wall caused less discomfort than a cool wall. A cool ceiling caused less discomfort than a warm ceiling. Accepting that 5% of the subjects may feel uncomfortable. a radiant temperature asymmetry of 10°C is allowable at a cool wall, 23°C at a warm wall, and 14°C under a cool ceiling. A previous study showed that 4°C is allowable under a warm ceiling. Radiant asymmetry had no significant impact on the operative temperatures preferred by the subjects. No significant differences were observed between the responses of men and women exposed to radiant asymmetry.
UR - http://www.scopus.com/inward/record.url?scp=0022112257&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0022112257&partnerID=8YFLogxK
U2 - 10.1016/0378-7788(85)90006-4
DO - 10.1016/0378-7788(85)90006-4
M3 - Article
AN - SCOPUS:0022112257
VL - 8
SP - 225
EP - 236
JO - Energy and Buildings
JF - Energy and Buildings
SN - 0378-7788
IS - 3
ER -