Compact Braille display using SMA wire array

Feng Zhao*, Keishi Fukuyama, Hideyuki Sawada

*この研究の対応する著者

研究成果: Conference contribution

25 被引用数 (Scopus)

抄録

A novel micro-vibration actuator using a shape-memory alloy (SMA) wire is being developed for the presentation of tactile sensations to a human skin. In this study, the SMA wire is arranged two dimensionally to construct a compact Braille display for the blind. The display is driven by electric current pulse for mobile use to present Braille information. The display was evaluated in a school for the blind, and the results are presented in the paper.

本文言語English
ホスト出版物のタイトルRO-MAN 2009 - 18th IEEE International Symposium on Robot and Human Interactive