Comparison of Older and Newer Generation Active Style Pro Accelerometers in Physical Activity and Sedentary Behavior Surveillance under a Free-Living Environment

Shohei Yano, MohammadJavad Koohsari, Ai Shibata, Kaori Ishii, Levi Frehlich, Gavin R. McCormack, Koichiro Oka

研究成果: Article

抄録

Background. Comparability of accelerometers in epidemiological studies is important for public health researchers. This study aimed to compare physical activity (light, LPA; moderate, MPA; and moderate-to-vigorous, MVPA) and sedentary behavior (SB) data collected using two Omron triaxial accelerometer generations (Active style Pro, ASP) among a sample of Japanese workers in a free-living environment. Methods. Thirty active and sedentary workers (24-62 years) wore two types of ASP accelerometers, the HJA-350IT (350IT) and the HJA-750C (750C), simultaneously for seven consecutive days to represent a typical week. The accelerometers estimated daily average step counts and time spent per day in LPA, MPA, and MVPA. If a participant had data for ≥4 days (>10 h/day) it was considered valid. The difference and agreement between the two ASPs were analyzed using a paired t-test, intra-class correlation coefficients (ICC), and a Bland-Altman analysis in total and for each type of worker. Results. Among all workers, the 750C measured significantly (p < 0.05) less SB, MPA, MVPA, and more LPA compared with the 350IT. The agreements in ICC were high (ICC ≥ 0.94). Conclusions. Compared with the 350IT, the newer generation 750C ASP accelerometer may not provide equivalent estimates of activity time, regardless of the type of physical activity.

元の言語English
ジャーナルInternational journal of environmental research and public health
16
発行部数9
DOI
出版物ステータスPublished - 2019 5 7

Fingerprint

Exercise
Epidemiologic Studies
Public Health
Research Personnel
Light

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health
  • Health, Toxicology and Mutagenesis

これを引用

@article{1fa994cc921d412391e9315647849b96,
title = "Comparison of Older and Newer Generation Active Style Pro Accelerometers in Physical Activity and Sedentary Behavior Surveillance under a Free-Living Environment",
abstract = "Background. Comparability of accelerometers in epidemiological studies is important for public health researchers. This study aimed to compare physical activity (light, LPA; moderate, MPA; and moderate-to-vigorous, MVPA) and sedentary behavior (SB) data collected using two Omron triaxial accelerometer generations (Active style Pro, ASP) among a sample of Japanese workers in a free-living environment. Methods. Thirty active and sedentary workers (24-62 years) wore two types of ASP accelerometers, the HJA-350IT (350IT) and the HJA-750C (750C), simultaneously for seven consecutive days to represent a typical week. The accelerometers estimated daily average step counts and time spent per day in LPA, MPA, and MVPA. If a participant had data for ≥4 days (>10 h/day) it was considered valid. The difference and agreement between the two ASPs were analyzed using a paired t-test, intra-class correlation coefficients (ICC), and a Bland-Altman analysis in total and for each type of worker. Results. Among all workers, the 750C measured significantly (p < 0.05) less SB, MPA, MVPA, and more LPA compared with the 350IT. The agreements in ICC were high (ICC ≥ 0.94). Conclusions. Compared with the 350IT, the newer generation 750C ASP accelerometer may not provide equivalent estimates of activity time, regardless of the type of physical activity.",
keywords = "accelerometry, monitoring, motion sensors, objective assessment",
author = "Shohei Yano and MohammadJavad Koohsari and Ai Shibata and Kaori Ishii and Levi Frehlich and McCormack, {Gavin R.} and Koichiro Oka",
year = "2019",
month = "5",
day = "7",
doi = "10.3390/ijerph16091597",
language = "English",
volume = "16",
journal = "International Journal of Environmental Research and Public Health",
issn = "1661-7827",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "9",

}

TY - JOUR

T1 - Comparison of Older and Newer Generation Active Style Pro Accelerometers in Physical Activity and Sedentary Behavior Surveillance under a Free-Living Environment

AU - Yano, Shohei

AU - Koohsari, MohammadJavad

AU - Shibata, Ai

AU - Ishii, Kaori

AU - Frehlich, Levi

AU - McCormack, Gavin R.

AU - Oka, Koichiro

PY - 2019/5/7

Y1 - 2019/5/7

N2 - Background. Comparability of accelerometers in epidemiological studies is important for public health researchers. This study aimed to compare physical activity (light, LPA; moderate, MPA; and moderate-to-vigorous, MVPA) and sedentary behavior (SB) data collected using two Omron triaxial accelerometer generations (Active style Pro, ASP) among a sample of Japanese workers in a free-living environment. Methods. Thirty active and sedentary workers (24-62 years) wore two types of ASP accelerometers, the HJA-350IT (350IT) and the HJA-750C (750C), simultaneously for seven consecutive days to represent a typical week. The accelerometers estimated daily average step counts and time spent per day in LPA, MPA, and MVPA. If a participant had data for ≥4 days (>10 h/day) it was considered valid. The difference and agreement between the two ASPs were analyzed using a paired t-test, intra-class correlation coefficients (ICC), and a Bland-Altman analysis in total and for each type of worker. Results. Among all workers, the 750C measured significantly (p < 0.05) less SB, MPA, MVPA, and more LPA compared with the 350IT. The agreements in ICC were high (ICC ≥ 0.94). Conclusions. Compared with the 350IT, the newer generation 750C ASP accelerometer may not provide equivalent estimates of activity time, regardless of the type of physical activity.

AB - Background. Comparability of accelerometers in epidemiological studies is important for public health researchers. This study aimed to compare physical activity (light, LPA; moderate, MPA; and moderate-to-vigorous, MVPA) and sedentary behavior (SB) data collected using two Omron triaxial accelerometer generations (Active style Pro, ASP) among a sample of Japanese workers in a free-living environment. Methods. Thirty active and sedentary workers (24-62 years) wore two types of ASP accelerometers, the HJA-350IT (350IT) and the HJA-750C (750C), simultaneously for seven consecutive days to represent a typical week. The accelerometers estimated daily average step counts and time spent per day in LPA, MPA, and MVPA. If a participant had data for ≥4 days (>10 h/day) it was considered valid. The difference and agreement between the two ASPs were analyzed using a paired t-test, intra-class correlation coefficients (ICC), and a Bland-Altman analysis in total and for each type of worker. Results. Among all workers, the 750C measured significantly (p < 0.05) less SB, MPA, MVPA, and more LPA compared with the 350IT. The agreements in ICC were high (ICC ≥ 0.94). Conclusions. Compared with the 350IT, the newer generation 750C ASP accelerometer may not provide equivalent estimates of activity time, regardless of the type of physical activity.

KW - accelerometry

KW - monitoring

KW - motion sensors

KW - objective assessment

UR - http://www.scopus.com/inward/record.url?scp=85065756640&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85065756640&partnerID=8YFLogxK

U2 - 10.3390/ijerph16091597

DO - 10.3390/ijerph16091597

M3 - Article

C2 - 31067688

AN - SCOPUS:85065756640

VL - 16

JO - International Journal of Environmental Research and Public Health

JF - International Journal of Environmental Research and Public Health

SN - 1661-7827

IS - 9

ER -