Complex check-like cross-sectional flow formation for fiber-shaped materials

研究成果: Conference contribution

抄録

We developed functional sheath flow of specific cross section using 3D stacked PDMS structure. The device was fabricated by four layer PDMS structures consist of two cylindrical channels with cross injection inlets. In the multi-stacked 3D device, check-like cross section on a cylindrical flow was successfully formed and 100μm diameter alginate fiber of single core divided into four parts was achieved.

元の言語English
ホスト出版物のタイトル20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016
出版者Chemical and Biological Microsystems Society
ページ836-837
ページ数2
ISBN(電子版)9780979806490
出版物ステータスPublished - 2016
イベント20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016 - Dublin, Ireland
継続期間: 2016 10 92016 10 13

Other

Other20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016
Ireland
Dublin
期間16/10/916/10/13

Fingerprint

Alginate
Fibers

ASJC Scopus subject areas

  • Control and Systems Engineering

これを引用

Kobayashi, K., Yoon, D., Sekiguchi, T., & Shoji, S. (2016). Complex check-like cross-sectional flow formation for fiber-shaped materials. : 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016 (pp. 836-837). Chemical and Biological Microsystems Society.

Complex check-like cross-sectional flow formation for fiber-shaped materials. / Kobayashi, K.; Yoon, Donghyun; Sekiguchi, Tetsushi; Shoji, Shuichi.

20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016. Chemical and Biological Microsystems Society, 2016. p. 836-837.

研究成果: Conference contribution

Kobayashi, K, Yoon, D, Sekiguchi, T & Shoji, S 2016, Complex check-like cross-sectional flow formation for fiber-shaped materials. : 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016. Chemical and Biological Microsystems Society, pp. 836-837, 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016, Dublin, Ireland, 16/10/9.
Kobayashi K, Yoon D, Sekiguchi T, Shoji S. Complex check-like cross-sectional flow formation for fiber-shaped materials. : 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016. Chemical and Biological Microsystems Society. 2016. p. 836-837
Kobayashi, K. ; Yoon, Donghyun ; Sekiguchi, Tetsushi ; Shoji, Shuichi. / Complex check-like cross-sectional flow formation for fiber-shaped materials. 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016. Chemical and Biological Microsystems Society, 2016. pp. 836-837
@inproceedings{98683c1c15bb4f789d381185f940eabf,
title = "Complex check-like cross-sectional flow formation for fiber-shaped materials",
abstract = "We developed functional sheath flow of specific cross section using 3D stacked PDMS structure. The device was fabricated by four layer PDMS structures consist of two cylindrical channels with cross injection inlets. In the multi-stacked 3D device, check-like cross section on a cylindrical flow was successfully formed and 100μm diameter alginate fiber of single core divided into four parts was achieved.",
keywords = "3D microfluidics, Fiber, Sheath flow",
author = "K. Kobayashi and Donghyun Yoon and Tetsushi Sekiguchi and Shuichi Shoji",
year = "2016",
language = "English",
pages = "836--837",
booktitle = "20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016",
publisher = "Chemical and Biological Microsystems Society",

}

TY - GEN

T1 - Complex check-like cross-sectional flow formation for fiber-shaped materials

AU - Kobayashi, K.

AU - Yoon, Donghyun

AU - Sekiguchi, Tetsushi

AU - Shoji, Shuichi

PY - 2016

Y1 - 2016

N2 - We developed functional sheath flow of specific cross section using 3D stacked PDMS structure. The device was fabricated by four layer PDMS structures consist of two cylindrical channels with cross injection inlets. In the multi-stacked 3D device, check-like cross section on a cylindrical flow was successfully formed and 100μm diameter alginate fiber of single core divided into four parts was achieved.

AB - We developed functional sheath flow of specific cross section using 3D stacked PDMS structure. The device was fabricated by four layer PDMS structures consist of two cylindrical channels with cross injection inlets. In the multi-stacked 3D device, check-like cross section on a cylindrical flow was successfully formed and 100μm diameter alginate fiber of single core divided into four parts was achieved.

KW - 3D microfluidics

KW - Fiber

KW - Sheath flow

UR - http://www.scopus.com/inward/record.url?scp=85014191351&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85014191351&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:85014191351

SP - 836

EP - 837

BT - 20th International Conference on Miniaturized Systems for Chemistry and Life Sciences, MicroTAS 2016

PB - Chemical and Biological Microsystems Society

ER -