Concept and feasibility study of specification for future waterproofing systems

Kyoji Tanaka, Hitoshi Yamada, Naoyuki Koshiishi, Mikio Tanabe, Yuji Nakazawa, Hideyuki Kajita

    研究成果: Article

    2 引用 (Scopus)

    抄録

    Next generation waterproofing specifications were discussed in the paper. Much amount of greenhouse gas emission and much cost during service life of 100 years were pointed out through the LCCO2 and LCC calculations of waterproofing membranes renovated by the present specifications. For reducing them, two types of specifications for future waterproofing system, such as an envelope type specification of requiring very few times renovation and a built-in type specification of not requiring renovation, were proposed. The calculated results for the proposed specifications by the new concept show much amount of reduction in LCCO<inf>2</inf> and LCC.

    元の言語English
    ページ(範囲)681-687
    ページ数7
    ジャーナルJournal of Structural and Construction Engineering
    79
    発行部数700
    DOI
    出版物ステータスPublished - 2014

    Fingerprint

    Waterproofing
    Specifications
    Gas emissions
    Greenhouse gases
    Service life
    Membranes
    Costs

    ASJC Scopus subject areas

    • Building and Construction
    • Architecture

    これを引用

    Concept and feasibility study of specification for future waterproofing systems. / Tanaka, Kyoji; Yamada, Hitoshi; Koshiishi, Naoyuki; Tanabe, Mikio; Nakazawa, Yuji; Kajita, Hideyuki.

    :: Journal of Structural and Construction Engineering, 巻 79, 番号 700, 2014, p. 681-687.

    研究成果: Article

    Tanaka, Kyoji ; Yamada, Hitoshi ; Koshiishi, Naoyuki ; Tanabe, Mikio ; Nakazawa, Yuji ; Kajita, Hideyuki. / Concept and feasibility study of specification for future waterproofing systems. :: Journal of Structural and Construction Engineering. 2014 ; 巻 79, 番号 700. pp. 681-687.
    @article{4abf5c077258499f9015d44418867bc3,
    title = "Concept and feasibility study of specification for future waterproofing systems",
    abstract = "Next generation waterproofing specifications were discussed in the paper. Much amount of greenhouse gas emission and much cost during service life of 100 years were pointed out through the LCCO2 and LCC calculations of waterproofing membranes renovated by the present specifications. For reducing them, two types of specifications for future waterproofing system, such as an envelope type specification of requiring very few times renovation and a built-in type specification of not requiring renovation, were proposed. The calculated results for the proposed specifications by the new concept show much amount of reduction in LCCO2 and LCC.",
    keywords = "Environmental loading reduction, LCC, Sustainable building, Waterproofing membrane",
    author = "Kyoji Tanaka and Hitoshi Yamada and Naoyuki Koshiishi and Mikio Tanabe and Yuji Nakazawa and Hideyuki Kajita",
    year = "2014",
    doi = "10.3130/aijs.79.681",
    language = "English",
    volume = "79",
    pages = "681--687",
    journal = "Journal of Structural and Construction Engineering",
    issn = "1340-4202",
    publisher = "Architectural Institute of Japan",
    number = "700",

    }

    TY - JOUR

    T1 - Concept and feasibility study of specification for future waterproofing systems

    AU - Tanaka, Kyoji

    AU - Yamada, Hitoshi

    AU - Koshiishi, Naoyuki

    AU - Tanabe, Mikio

    AU - Nakazawa, Yuji

    AU - Kajita, Hideyuki

    PY - 2014

    Y1 - 2014

    N2 - Next generation waterproofing specifications were discussed in the paper. Much amount of greenhouse gas emission and much cost during service life of 100 years were pointed out through the LCCO2 and LCC calculations of waterproofing membranes renovated by the present specifications. For reducing them, two types of specifications for future waterproofing system, such as an envelope type specification of requiring very few times renovation and a built-in type specification of not requiring renovation, were proposed. The calculated results for the proposed specifications by the new concept show much amount of reduction in LCCO2 and LCC.

    AB - Next generation waterproofing specifications were discussed in the paper. Much amount of greenhouse gas emission and much cost during service life of 100 years were pointed out through the LCCO2 and LCC calculations of waterproofing membranes renovated by the present specifications. For reducing them, two types of specifications for future waterproofing system, such as an envelope type specification of requiring very few times renovation and a built-in type specification of not requiring renovation, were proposed. The calculated results for the proposed specifications by the new concept show much amount of reduction in LCCO2 and LCC.

    KW - Environmental loading reduction

    KW - LCC

    KW - Sustainable building

    KW - Waterproofing membrane

    UR - http://www.scopus.com/inward/record.url?scp=84940259093&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84940259093&partnerID=8YFLogxK