抄録
The interruption of power supply is one of the major technical issues in rotation angle sensorless controls of PMSMs. This causes failures of inverter operation due to voltage drop in filter capacitor (FC). In order to solve this technical issue, we propose a method to achieve continuous operation of PMSMs with low inertia loads, for example compressors of air conditioners, in case of power supply interruption. In the proposed method, the current reference is determined according to the relationship between the kinetic energy of the motor and the electrical energy of the FC to effectively use the available energy. The proposed method is validated by experimental test of 1-kW class PMSM.
本文言語 | English |
---|---|
ページ(範囲) | 687-695 |
ページ数 | 9 |
ジャーナル | IEEJ Transactions on Industry Applications |
巻 | 137 |
号 | 9 |
DOI | |
出版ステータス | Published - 2017 1月 1 |
外部発表 | はい |
ASJC Scopus subject areas
- 産業および生産工学
- 電子工学および電気工学