Continuous operation control of PMSM with compressor loads of air conditioners in case of DC power supply loss

Jongwon Heo*, Kentaro Matsuo, Kenji Natori, Keiichiro Kondo

*この研究の対応する著者

研究成果: Article査読

2 被引用数 (Scopus)

抄録

The interruption of power supply is one of the major technical issues in rotation angle sensorless controls of PMSMs. This causes failures of inverter operation due to voltage drop in filter capacitor (FC). In order to solve this technical issue, we propose a method to achieve continuous operation of PMSMs with low inertia loads, for example compressors of air conditioners, in case of power supply interruption. In the proposed method, the current reference is determined according to the relationship between the kinetic energy of the motor and the electrical energy of the FC to effectively use the available energy. The proposed method is validated by experimental test of 1-kW class PMSM.

本文言語English
ページ(範囲)687-695
ページ数9
ジャーナルIEEJ Transactions on Industry Applications
137
9
DOI
出版ステータスPublished - 2017 1月 1
外部発表はい

ASJC Scopus subject areas

  • 産業および生産工学
  • 電子工学および電気工学

フィンガープリント

「Continuous operation control of PMSM with compressor loads of air conditioners in case of DC power supply loss」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル