Direct observation of internal state of thermal runaway in lithium ion battery during nail-penetration test

Tokihiko Yokoshima, Daikichi Mukoyama, Fujio Maeda, Tetsuya Osaka, Koji Takazawa, Shun Egusa, Satomi Naoi, Satoru Ishikura, Koichi Yamamoto

研究成果: Article

13 引用 (Scopus)

抜粋

A system using a high-speed and high-precision X-ray inspection system for testing internal short circuits in lithium-ion batteries (LIBs) was firstly developed for the safety test on LIBs. X-ray transmission moving images of the anode and cathode were obtained in the layered LIB structure. The nail-penetration test was chosen to test for the presence of an internal short circuit. This system would allow direct observation of smoke generation inside outside the battery, ballooning of the pouch, as well as changing layered structures of electrodes in real time. Since the results of a conventional nail-penetration test are indicated only by smoke generation, fire, or explosion, this new system allows electrode changes in the pouch to be observed for the first time. This system is expected to lead to great developments in the safety of LIBs.

元の言語English
ページ(範囲)67-74
ページ数8
ジャーナルJournal of Power Sources
393
DOI
出版物ステータスPublished - 2018 7 31

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment
  • Energy Engineering and Power Technology
  • Physical and Theoretical Chemistry
  • Electrical and Electronic Engineering

フィンガープリント Direct observation of internal state of thermal runaway in lithium ion battery during nail-penetration test' の研究トピックを掘り下げます。これらはともに一意のフィンガープリントを構成します。