Effect of pressure intensity of graduated elastic compression stocking on muscle fatigue following calf-raise exercise

Naokazu Miyamoto, Kosuke Hirata, Naotoshi Mitsukawa, Toshimasa Yanai, Yasuo Kawakami

研究成果: Article

33 引用 (Scopus)

抄録

The purpose of the present study was to examine the effects of wearing a graduated elastic compression (EC) stocking, with different pressure profiles during a fatiguing calf-raise exercise session, on the torque generating capacity after exercise. Fourteen subjects performed 15 sets of 10 repetitions of calf-raise exercise, wearing one of three stockings of different compression pressure profiles: two kinds of EC stockings (one (EC30) with 30. mm. Hg at the ankle, 21-25 mm Hg at the calf, and 10. mm. Hg below the knee, and the other (EC18) with 18, 12-14, and 7 mm Hg at the same regions, respectively) and a non-EC sport stocking as a control (CON). Before and after the exercise, torque and electromyographic (EMG) signals of medial gastrocnemius and soleus muscles were recorded during an evoked triplet contraction and the maximal voluntary contraction (MVC). All stockings had no effect on the decline of the MVC torque whereas the reduction of the evoke triplet torque in EC30 stocking condition was significantly smaller compared with that in CON (-6.4 ± 8.5% for EC30 and -16.5 ± 9.0% for CON, P<0.05). The reduction of the mean power frequency of EMG during MVC in the EC30 condition was significantly smaller than that in CON (-4.4 ± 10.9. Hz for EC30 and -18.7 ± 7.9. Hz for CON, P<0.05). These results suggest that the EC stocking with adequate pressure at the calf region relieves muscle fatigue of the triceps surae induced by calf-raise exercise.

元の言語English
ページ(範囲)249-254
ページ数6
ジャーナルJournal of Electromyography and Kinesiology
21
発行部数2
DOI
出版物ステータスPublished - 2011 4

Fingerprint

Compression Stockings
Muscle Fatigue
Pressure
Torque
Skeletal Muscle
Ankle
Sports
Knee

ASJC Scopus subject areas

  • Neuroscience (miscellaneous)
  • Biophysics
  • Clinical Neurology

これを引用

@article{246a015039ce41c9bedb26ce8b8f6590,
title = "Effect of pressure intensity of graduated elastic compression stocking on muscle fatigue following calf-raise exercise",
abstract = "The purpose of the present study was to examine the effects of wearing a graduated elastic compression (EC) stocking, with different pressure profiles during a fatiguing calf-raise exercise session, on the torque generating capacity after exercise. Fourteen subjects performed 15 sets of 10 repetitions of calf-raise exercise, wearing one of three stockings of different compression pressure profiles: two kinds of EC stockings (one (EC30) with 30. mm. Hg at the ankle, 21-25 mm Hg at the calf, and 10. mm. Hg below the knee, and the other (EC18) with 18, 12-14, and 7 mm Hg at the same regions, respectively) and a non-EC sport stocking as a control (CON). Before and after the exercise, torque and electromyographic (EMG) signals of medial gastrocnemius and soleus muscles were recorded during an evoked triplet contraction and the maximal voluntary contraction (MVC). All stockings had no effect on the decline of the MVC torque whereas the reduction of the evoke triplet torque in EC30 stocking condition was significantly smaller compared with that in CON (-6.4 ± 8.5{\%} for EC30 and -16.5 ± 9.0{\%} for CON, P<0.05). The reduction of the mean power frequency of EMG during MVC in the EC30 condition was significantly smaller than that in CON (-4.4 ± 10.9. Hz for EC30 and -18.7 ± 7.9. Hz for CON, P<0.05). These results suggest that the EC stocking with adequate pressure at the calf region relieves muscle fatigue of the triceps surae induced by calf-raise exercise.",
keywords = "Electromyography, Evoked contraction, Maximal voluntary contraction, Mean power frequency",
author = "Naokazu Miyamoto and Kosuke Hirata and Naotoshi Mitsukawa and Toshimasa Yanai and Yasuo Kawakami",
year = "2011",
month = "4",
doi = "10.1016/j.jelekin.2010.08.006",
language = "English",
volume = "21",
pages = "249--254",
journal = "Journal of Electromyography and Kinesiology",
issn = "1050-6411",
publisher = "Elsevier Limited",
number = "2",

}

TY - JOUR

T1 - Effect of pressure intensity of graduated elastic compression stocking on muscle fatigue following calf-raise exercise

AU - Miyamoto, Naokazu

AU - Hirata, Kosuke

AU - Mitsukawa, Naotoshi

AU - Yanai, Toshimasa

AU - Kawakami, Yasuo

PY - 2011/4

Y1 - 2011/4

N2 - The purpose of the present study was to examine the effects of wearing a graduated elastic compression (EC) stocking, with different pressure profiles during a fatiguing calf-raise exercise session, on the torque generating capacity after exercise. Fourteen subjects performed 15 sets of 10 repetitions of calf-raise exercise, wearing one of three stockings of different compression pressure profiles: two kinds of EC stockings (one (EC30) with 30. mm. Hg at the ankle, 21-25 mm Hg at the calf, and 10. mm. Hg below the knee, and the other (EC18) with 18, 12-14, and 7 mm Hg at the same regions, respectively) and a non-EC sport stocking as a control (CON). Before and after the exercise, torque and electromyographic (EMG) signals of medial gastrocnemius and soleus muscles were recorded during an evoked triplet contraction and the maximal voluntary contraction (MVC). All stockings had no effect on the decline of the MVC torque whereas the reduction of the evoke triplet torque in EC30 stocking condition was significantly smaller compared with that in CON (-6.4 ± 8.5% for EC30 and -16.5 ± 9.0% for CON, P<0.05). The reduction of the mean power frequency of EMG during MVC in the EC30 condition was significantly smaller than that in CON (-4.4 ± 10.9. Hz for EC30 and -18.7 ± 7.9. Hz for CON, P<0.05). These results suggest that the EC stocking with adequate pressure at the calf region relieves muscle fatigue of the triceps surae induced by calf-raise exercise.

AB - The purpose of the present study was to examine the effects of wearing a graduated elastic compression (EC) stocking, with different pressure profiles during a fatiguing calf-raise exercise session, on the torque generating capacity after exercise. Fourteen subjects performed 15 sets of 10 repetitions of calf-raise exercise, wearing one of three stockings of different compression pressure profiles: two kinds of EC stockings (one (EC30) with 30. mm. Hg at the ankle, 21-25 mm Hg at the calf, and 10. mm. Hg below the knee, and the other (EC18) with 18, 12-14, and 7 mm Hg at the same regions, respectively) and a non-EC sport stocking as a control (CON). Before and after the exercise, torque and electromyographic (EMG) signals of medial gastrocnemius and soleus muscles were recorded during an evoked triplet contraction and the maximal voluntary contraction (MVC). All stockings had no effect on the decline of the MVC torque whereas the reduction of the evoke triplet torque in EC30 stocking condition was significantly smaller compared with that in CON (-6.4 ± 8.5% for EC30 and -16.5 ± 9.0% for CON, P<0.05). The reduction of the mean power frequency of EMG during MVC in the EC30 condition was significantly smaller than that in CON (-4.4 ± 10.9. Hz for EC30 and -18.7 ± 7.9. Hz for CON, P<0.05). These results suggest that the EC stocking with adequate pressure at the calf region relieves muscle fatigue of the triceps surae induced by calf-raise exercise.

KW - Electromyography

KW - Evoked contraction

KW - Maximal voluntary contraction

KW - Mean power frequency

UR - http://www.scopus.com/inward/record.url?scp=79951510357&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79951510357&partnerID=8YFLogxK

U2 - 10.1016/j.jelekin.2010.08.006

DO - 10.1016/j.jelekin.2010.08.006

M3 - Article

C2 - 20843703

AN - SCOPUS:79951510357

VL - 21

SP - 249

EP - 254

JO - Journal of Electromyography and Kinesiology

JF - Journal of Electromyography and Kinesiology

SN - 1050-6411

IS - 2

ER -