N2 - Recently, the range of applications of surgical staplers has been extended to include laparoscopic liver resection because manipulation of a surgical stapler is very simple. Revealing the causes of stapling failure and suggesting a method to solve stapling failure are important for safe laparoscopic liver resection. Surgeons say that tissues make stapling more likely to fail if they are thick and brittle. However, the combinatorial effect of the thickness and stiffness of tissues on the success of surgical stapling for laparoscopic liver resection has not been investigated. Therefore, the objective of the present study was to investigate the effect of tissue thickness and tissue stiffness on the success rate (SR) of surgical stapling. From ex vivo stapling experimental results using pig livers, it is suggested that the effect of tissue thickness is greater than the effect of tissue stiffness on the SR of stapling. If tissue thickness is 5 mm, the SR of stapling is high regardless of the magnitude of the tissue-stiffness parameter. However, if tissue thickness is >10 mm, the SR of stapling has a relationship with nonlinear viscoelastic parameters. Therefore, the SR of stapling could be predicted from tissue thickness and nonlinear elastic parameters.
AB - Recently, the range of applications of surgical staplers has been extended to include laparoscopic liver resection because manipulation of a surgical stapler is very simple. Revealing the causes of stapling failure and suggesting a method to solve stapling failure are important for safe laparoscopic liver resection. Surgeons say that tissues make stapling more likely to fail if they are thick and brittle. However, the combinatorial effect of the thickness and stiffness of tissues on the success of surgical stapling for laparoscopic liver resection has not been investigated. Therefore, the objective of the present study was to investigate the effect of tissue thickness and tissue stiffness on the success rate (SR) of surgical stapling. From ex vivo stapling experimental results using pig livers, it is suggested that the effect of tissue thickness is greater than the effect of tissue stiffness on the SR of stapling. If tissue thickness is 5 mm, the SR of stapling is high regardless of the magnitude of the tissue-stiffness parameter. However, if tissue thickness is >10 mm, the SR of stapling has a relationship with nonlinear viscoelastic parameters. Therefore, the SR of stapling could be predicted from tissue thickness and nonlinear elastic parameters.
UR - http://www.scopus.com/inward/record.url?scp=84942422767&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84942422767&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2014.6943602
DO - 10.1109/EMBC.2014.6943602
M3 - Article
C2 - 25569970
VL - 2014
SP - 353
EP - 356
JO - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
JF - Conference proceedings : ... Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Conference
SN - 1557-170X
ER -