In this study, the effect of ultrasound exposure on number and scattering intensity from microbubbles in blood vessel model is noticed. Experimentally, microbubbles are produced using surfactant solution, and the measurement of number and scattering intensity of microbubbles are performed. Furthermore, theoretical calculation of scattering intensity from microbubbles in blood vessel model is performed to compare with experimental results. From the comparison of calculation and experiment, the effectiveness of constructed calculation model is confirmed.

元の言語English
ホスト出版物のタイトルAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
ページ2390-2394
ページ数5
26 IV
出版物ステータスPublished - 2004
イベントConference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004 - San Francisco, CA, United States
継続期間: 2004 9 12004 9 5

Other

OtherConference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004
United States
San Francisco, CA
期間04/9/104/9/5

Fingerprint

Surface-Active Agents
Surface active agents
Ultrasonics
Blood vessels
Scattering
Experiments

ASJC Scopus subject areas

  • Bioengineering

これを引用

Soetanto, K., & Saito, T. (2004). Effect of ultrasound exposure on surfactant microbubbles. : Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (巻 26 IV, pp. 2390-2394)

Effect of ultrasound exposure on surfactant microbubbles. / Soetanto, Kawan; Saito, Tomohiro.

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 巻 26 IV 2004. p. 2390-2394.

研究成果: Conference contribution

Soetanto, K & Saito, T 2004, Effect of ultrasound exposure on surfactant microbubbles. : Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 巻. 26 IV, pp. 2390-2394, Conference Proceedings - 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2004, San Francisco, CA, United States, 04/9/1.
Soetanto K, Saito T. Effect of ultrasound exposure on surfactant microbubbles. : Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 巻 26 IV. 2004. p. 2390-2394
Soetanto, Kawan ; Saito, Tomohiro. / Effect of ultrasound exposure on surfactant microbubbles. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 巻 26 IV 2004. pp. 2390-2394
@inproceedings{297e54925a9d488d946134f3e117834c,
title = "Effect of ultrasound exposure on surfactant microbubbles",
abstract = "In this study, the effect of ultrasound exposure on number and scattering intensity from microbubbles in blood vessel model is noticed. Experimentally, microbubbles are produced using surfactant solution, and the measurement of number and scattering intensity of microbubbles are performed. Furthermore, theoretical calculation of scattering intensity from microbubbles in blood vessel model is performed to compare with experimental results. From the comparison of calculation and experiment, the effectiveness of constructed calculation model is confirmed.",
keywords = "Microbubbles blood vessel model, Number, Scattering intensity, Ultrasound exposure",
author = "Kawan Soetanto and Tomohiro Saito",
year = "2004",
language = "English",
volume = "26 IV",
pages = "2390--2394",
booktitle = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",

}

TY - GEN

T1 - Effect of ultrasound exposure on surfactant microbubbles

AU - Soetanto, Kawan

AU - Saito, Tomohiro

PY - 2004

Y1 - 2004

N2 - In this study, the effect of ultrasound exposure on number and scattering intensity from microbubbles in blood vessel model is noticed. Experimentally, microbubbles are produced using surfactant solution, and the measurement of number and scattering intensity of microbubbles are performed. Furthermore, theoretical calculation of scattering intensity from microbubbles in blood vessel model is performed to compare with experimental results. From the comparison of calculation and experiment, the effectiveness of constructed calculation model is confirmed.

AB - In this study, the effect of ultrasound exposure on number and scattering intensity from microbubbles in blood vessel model is noticed. Experimentally, microbubbles are produced using surfactant solution, and the measurement of number and scattering intensity of microbubbles are performed. Furthermore, theoretical calculation of scattering intensity from microbubbles in blood vessel model is performed to compare with experimental results. From the comparison of calculation and experiment, the effectiveness of constructed calculation model is confirmed.

KW - Microbubbles blood vessel model

KW - Number

KW - Scattering intensity

KW - Ultrasound exposure

UR - http://www.scopus.com/inward/record.url?scp=11144275930&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=11144275930&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:11144275930

VL - 26 IV

SP - 2390

EP - 2394

BT - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

ER -