EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON.

Mitsuo Umezu, T. Yoshihara, H. Takano, K. Tsuchiya, T. Akutsu

研究成果: Conference contribution

抄録

When an artificial heart is driven, an extraordinary high spike pressure which is known as a water hammer (WH) phenomenon occurs in the vicinity of artificial heart valves. In this study, the authors make clear the effects of the artificial heart drive conditions on WH phenomenon in our three types of mock circulatory systems which simulate well the blood pressure-flow relationships of the in-vivo situation of total artificial heart, left ventricular assist device, and pulsatile extracorporeal circulation, respectively.

元の言語English
ホスト出版物のタイトルUnknown Host Publication Title
出版場所Oxford, Engl
出版者Pergamon Press
ページ305-310
ページ数6
ISBN(印刷物)0080316816
出版物ステータスPublished - 1986
外部発表Yes

Fingerprint

Artificial heart
Water hammer
Left ventricular assist devices
Blood pressure

ASJC Scopus subject areas

  • Engineering(all)

これを引用

Umezu, M., Yoshihara, T., Takano, H., Tsuchiya, K., & Akutsu, T. (1986). EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON.Unknown Host Publication Title (pp. 305-310). Oxford, Engl: Pergamon Press.

EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON. / Umezu, Mitsuo; Yoshihara, T.; Takano, H.; Tsuchiya, K.; Akutsu, T.

Unknown Host Publication Title. Oxford, Engl : Pergamon Press, 1986. p. 305-310.

研究成果: Conference contribution

Umezu, M, Yoshihara, T, Takano, H, Tsuchiya, K & Akutsu, T 1986, EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON.Unknown Host Publication Title. Pergamon Press, Oxford, Engl, pp. 305-310.
Umezu M, Yoshihara T, Takano H, Tsuchiya K, Akutsu T. EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON. : Unknown Host Publication Title. Oxford, Engl: Pergamon Press. 1986. p. 305-310
Umezu, Mitsuo ; Yoshihara, T. ; Takano, H. ; Tsuchiya, K. ; Akutsu, T. / EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON. Unknown Host Publication Title. Oxford, Engl : Pergamon Press, 1986. pp. 305-310
@inproceedings{26ca2298505e43f79f21f6f37ea741ab,
title = "EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON.",
abstract = "When an artificial heart is driven, an extraordinary high spike pressure which is known as a water hammer (WH) phenomenon occurs in the vicinity of artificial heart valves. In this study, the authors make clear the effects of the artificial heart drive conditions on WH phenomenon in our three types of mock circulatory systems which simulate well the blood pressure-flow relationships of the in-vivo situation of total artificial heart, left ventricular assist device, and pulsatile extracorporeal circulation, respectively.",
author = "Mitsuo Umezu and T. Yoshihara and H. Takano and K. Tsuchiya and T. Akutsu",
year = "1986",
language = "English",
isbn = "0080316816",
pages = "305--310",
booktitle = "Unknown Host Publication Title",
publisher = "Pergamon Press",

}

TY - GEN

T1 - EFFECTS OF ARTIFICIAL HEART DRIVE CONDITIONS ON WATER HAMMER PHENOMENON.

AU - Umezu, Mitsuo

AU - Yoshihara, T.

AU - Takano, H.

AU - Tsuchiya, K.

AU - Akutsu, T.

PY - 1986

Y1 - 1986

N2 - When an artificial heart is driven, an extraordinary high spike pressure which is known as a water hammer (WH) phenomenon occurs in the vicinity of artificial heart valves. In this study, the authors make clear the effects of the artificial heart drive conditions on WH phenomenon in our three types of mock circulatory systems which simulate well the blood pressure-flow relationships of the in-vivo situation of total artificial heart, left ventricular assist device, and pulsatile extracorporeal circulation, respectively.

AB - When an artificial heart is driven, an extraordinary high spike pressure which is known as a water hammer (WH) phenomenon occurs in the vicinity of artificial heart valves. In this study, the authors make clear the effects of the artificial heart drive conditions on WH phenomenon in our three types of mock circulatory systems which simulate well the blood pressure-flow relationships of the in-vivo situation of total artificial heart, left ventricular assist device, and pulsatile extracorporeal circulation, respectively.

UR - http://www.scopus.com/inward/record.url?scp=0023036138&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0023036138&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0023036138

SN - 0080316816

SP - 305

EP - 310

BT - Unknown Host Publication Title

PB - Pergamon Press

CY - Oxford, Engl

ER -