Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system

Miho Matsumura, Masayuki Ogata, Shinichi Tanabe, Satoshi Hori, Hitomi Tsutsumi

    研究成果: Paper

    抄録

    The objective of this study was to identify high-risk areas for contact infection by investigating incidences of contamination in hospital medical examination rooms and reviewing previous studies on the operating ranges of health care workers and patients. Investigation of contaminants was conducted using an Adenosine triphosphate (ATP) measurement method (EnSURE® & SuperSnap™; Hygiena, Camarillo, CA, USA)of 12 surfaces in two examination rooms. We detected an increase in contamination greater than 1000 relative light units (RLU) per 100 cm2 on the handrail of the doctor's chair, the doctor's desk, and the inner doorknob over the time medical service was provided. The doctor's desk and the handrails of the doctor's chair were highly contaminated, and this correlated with a longer time spent near these surfaces [1]. It was noted that doctors may lean on a handrail or a backrest for fatigue relief during a long medical examination. The extension of the handset was highly contaminated surface with greater than 1000 RLU detected both before and after work. It was speculated that medical workers were not as careful to clean because patients do not contact this place. It was suggested that the strength of contacting pressure make difference in contamination.

    元の言語English
    出版物ステータスPublished - 2015 1 1
    イベントHealthy Buildings Europe 2015, HB 2015 - Eindhoven, Netherlands
    継続期間: 2015 5 182015 5 20

    Other

    OtherHealthy Buildings Europe 2015, HB 2015
    Netherlands
    Eindhoven
    期間15/5/1815/5/20

    Fingerprint

    Railings
    Contamination
    Health care
    Fatigue of materials
    Impurities

    ASJC Scopus subject areas

    • Civil and Structural Engineering

    これを引用

    Matsumura, M., Ogata, M., Tanabe, S., Hori, S., & Tsutsumi, H. (2015). Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system. 論文発表場所 Healthy Buildings Europe 2015, HB 2015, Eindhoven, Netherlands.

    Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system. / Matsumura, Miho; Ogata, Masayuki; Tanabe, Shinichi; Hori, Satoshi; Tsutsumi, Hitomi.

    2015. 論文発表場所 Healthy Buildings Europe 2015, HB 2015, Eindhoven, Netherlands.

    研究成果: Paper

    Matsumura, M, Ogata, M, Tanabe, S, Hori, S & Tsutsumi, H 2015, 'Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system', 論文発表場所 Healthy Buildings Europe 2015, HB 2015, Eindhoven, Netherlands, 15/5/18 - 15/5/20.
    Matsumura M, Ogata M, Tanabe S, Hori S, Tsutsumi H. Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system. 2015. 論文発表場所 Healthy Buildings Europe 2015, HB 2015, Eindhoven, Netherlands.
    Matsumura, Miho ; Ogata, Masayuki ; Tanabe, Shinichi ; Hori, Satoshi ; Tsutsumi, Hitomi. / Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system. 論文発表場所 Healthy Buildings Europe 2015, HB 2015, Eindhoven, Netherlands.
    @conference{922c5ea56c5146ee9f523fa7d8f55730,
    title = "Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system",
    abstract = "The objective of this study was to identify high-risk areas for contact infection by investigating incidences of contamination in hospital medical examination rooms and reviewing previous studies on the operating ranges of health care workers and patients. Investigation of contaminants was conducted using an Adenosine triphosphate (ATP) measurement method (EnSURE{\circledR} & SuperSnap™; Hygiena, Camarillo, CA, USA)of 12 surfaces in two examination rooms. We detected an increase in contamination greater than 1000 relative light units (RLU) per 100 cm2 on the handrail of the doctor's chair, the doctor's desk, and the inner doorknob over the time medical service was provided. The doctor's desk and the handrails of the doctor's chair were highly contaminated, and this correlated with a longer time spent near these surfaces [1]. It was noted that doctors may lean on a handrail or a backrest for fatigue relief during a long medical examination. The extension of the handset was highly contaminated surface with greater than 1000 RLU detected both before and after work. It was speculated that medical workers were not as careful to clean because patients do not contact this place. It was suggested that the strength of contacting pressure make difference in contamination.",
    keywords = "ATP measurement method, Contact infection, Medical examination room",
    author = "Miho Matsumura and Masayuki Ogata and Shinichi Tanabe and Satoshi Hori and Hitomi Tsutsumi",
    year = "2015",
    month = "1",
    day = "1",
    language = "English",
    note = "Healthy Buildings Europe 2015, HB 2015 ; Conference date: 18-05-2015 Through 20-05-2015",

    }

    TY - CONF

    T1 - Evaluation of environmental surface contamination in medical examination rooms using an ATP measurement system

    AU - Matsumura, Miho

    AU - Ogata, Masayuki

    AU - Tanabe, Shinichi

    AU - Hori, Satoshi

    AU - Tsutsumi, Hitomi

    PY - 2015/1/1

    Y1 - 2015/1/1

    N2 - The objective of this study was to identify high-risk areas for contact infection by investigating incidences of contamination in hospital medical examination rooms and reviewing previous studies on the operating ranges of health care workers and patients. Investigation of contaminants was conducted using an Adenosine triphosphate (ATP) measurement method (EnSURE® & SuperSnap™; Hygiena, Camarillo, CA, USA)of 12 surfaces in two examination rooms. We detected an increase in contamination greater than 1000 relative light units (RLU) per 100 cm2 on the handrail of the doctor's chair, the doctor's desk, and the inner doorknob over the time medical service was provided. The doctor's desk and the handrails of the doctor's chair were highly contaminated, and this correlated with a longer time spent near these surfaces [1]. It was noted that doctors may lean on a handrail or a backrest for fatigue relief during a long medical examination. The extension of the handset was highly contaminated surface with greater than 1000 RLU detected both before and after work. It was speculated that medical workers were not as careful to clean because patients do not contact this place. It was suggested that the strength of contacting pressure make difference in contamination.

    AB - The objective of this study was to identify high-risk areas for contact infection by investigating incidences of contamination in hospital medical examination rooms and reviewing previous studies on the operating ranges of health care workers and patients. Investigation of contaminants was conducted using an Adenosine triphosphate (ATP) measurement method (EnSURE® & SuperSnap™; Hygiena, Camarillo, CA, USA)of 12 surfaces in two examination rooms. We detected an increase in contamination greater than 1000 relative light units (RLU) per 100 cm2 on the handrail of the doctor's chair, the doctor's desk, and the inner doorknob over the time medical service was provided. The doctor's desk and the handrails of the doctor's chair were highly contaminated, and this correlated with a longer time spent near these surfaces [1]. It was noted that doctors may lean on a handrail or a backrest for fatigue relief during a long medical examination. The extension of the handset was highly contaminated surface with greater than 1000 RLU detected both before and after work. It was speculated that medical workers were not as careful to clean because patients do not contact this place. It was suggested that the strength of contacting pressure make difference in contamination.

    KW - ATP measurement method

    KW - Contact infection

    KW - Medical examination room

    UR - http://www.scopus.com/inward/record.url?scp=85052387942&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=85052387942&partnerID=8YFLogxK

    M3 - Paper

    AN - SCOPUS:85052387942

    ER -