抄録
In this study, thermal load suppressant effect to the inside and outside of building covered with heat-treatment wood was evaluated with ten kinds of fabricated model structure with concrete. The surface temperature of the daytime wooden cladding became higher than the concrete surface, and thermal load to the atmosphere grew big. On the other hand, on after the evening when solar radiation became weak, the surface temperature decreased rapidly. The conductive heat flux was smaller than the concrete surface without the cladding, and transfer of heat was suppressed throughout the day.
本文言語 | English |
---|---|
ページ(範囲) | 689-692 |
ページ数 | 4 |
ジャーナル | AIJ Journal of Technology and Design |
巻 | 21 |
号 | 48 |
DOI | |
出版ステータス | Published - 2015 6月 |
外部発表 | はい |
ASJC Scopus subject areas