Experimental analysis of diffuser rotating stall in a three-stage centrifugal pump

Taiki Takamine, Daichi Furukawa, Satoshi Watanabe*, Hiroyoshi Watanabe, Kazuyoshi Miyagawa

*この研究の対応する著者

研究成果: Article査読

7 被引用数 (Scopus)

抄録

Rotating stall phenomenon limits the operation range of turbomacnines, therefore it is important to understand the crucial parameters of this phenomenon. In the present study, the diffuser rotating stall in a three-stage centrifugal pump was experimentally studied. Examined main parameter was an axial offset of rotor against the stationary part, which might be unavoidable due to accumulation of geometrical tolerances and assembling errors. The effect of leakage flow rate at the balance drum section employed as a thrust balancing device, which increases the thru-flow rate at the first and second stages diffusers. was also studied. The effect of rotor axial offset was clearly observed and, with the rotor axial offset to the suction side, the rotating stall appeared only at the third stage diffuser. By setting the balance flow rate set to zero, the onset range of rotating stall became wider m the first and second stage diffusers, which was well explained by the decrease of the thru-flow rate.

本文言語English
ページ(範囲)77-84
ページ数8
ジャーナルInternational Journal of Fluid Machinery and Systems
11
1
DOI
出版ステータスPublished - 2018 1月 1

ASJC Scopus subject areas

  • 機械工学
  • 産業および生産工学

フィンガープリント

「Experimental analysis of diffuser rotating stall in a three-stage centrifugal pump」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル