TY - JOUR
T1 - Experimental verification of application of looped system and centralized voltage control in a distribution system with Renewable Energy Sources
AU - Hanai, Yuji
AU - Hayashi, Yasuhiro
AU - Matsuki, Junya
PY - 2010
Y1 - 2010
N2 - The line voltage control in a distribution network is one of the most important issues for a penetration of Renewable Energy Sources (RES). A loop distribution network configuration is an effective solution to resolve voltage and distribution loss issues concerned about a penetration of RES. In this paper, for a loop distribution network, the authors propose a voltage control method based on tap change control of LRT and active/reactive power control of RES. The tap change control of LRT takes a major role of the proposed voltage control. Additionally the active/reactive power control of RES supports the voltage control when voltage deviation from the upper or lower voltage limit is unavoidable. The proposed method adopts SCADA system based on measured data from IT switches, which are sectionalizing switch with sensor installed in distribution feeder. In order to check the validity of the proposed voltage control method, experimental simulations using a distribution system analog simulator "ANSWER" are carried out. In the simulations, the voltage maintenance capability in the normal and the emergency is evaluated.
AB - The line voltage control in a distribution network is one of the most important issues for a penetration of Renewable Energy Sources (RES). A loop distribution network configuration is an effective solution to resolve voltage and distribution loss issues concerned about a penetration of RES. In this paper, for a loop distribution network, the authors propose a voltage control method based on tap change control of LRT and active/reactive power control of RES. The tap change control of LRT takes a major role of the proposed voltage control. Additionally the active/reactive power control of RES supports the voltage control when voltage deviation from the upper or lower voltage limit is unavoidable. The proposed method adopts SCADA system based on measured data from IT switches, which are sectionalizing switch with sensor installed in distribution feeder. In order to check the validity of the proposed voltage control method, experimental simulations using a distribution system analog simulator "ANSWER" are carried out. In the simulations, the voltage maintenance capability in the normal and the emergency is evaluated.
KW - Distribution system analog simulator
KW - LRT
KW - Loop distribution network
KW - Renewable energy
KW - Voltage control
UR - http://www.scopus.com/inward/record.url?scp=78650374870&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78650374870&partnerID=8YFLogxK
U2 - 10.1541/ieejpes.130.932
DO - 10.1541/ieejpes.130.932
M3 - Article
AN - SCOPUS:78650374870
VL - 130
SP - 932
EP - 940
JO - IEEJ Transactions on Power and Energy
JF - IEEJ Transactions on Power and Energy
SN - 0385-4213
IS - 11