Fault location in a cable for a nuclear power plant by frequency domain reflectometry

研究成果: Conference contribution

11 被引用数 (Scopus)

抄録

Cables installed in nuclear power plants are subjected to thermal burden and radioactive rays. Regarding this, if we want to monitor the integrity of a cable in a nuclear power plant continuously, we have to do measurements while the cable is heated and irradiated. In this research, we obtained frequency domain reflectometry signals for a 50-m long cable insulated with flame-retardant ethylene propylene diene copolymer (FR-EPDM) installed in an environment where heat and radiation were given simultaneously. Then, we separated signals originating in the degradation of the insulation from those due to heat and radiation. This result indicates that the separation of the signal arising from the degradation of insulation from other signals due to heat and radiation is in principle possible at least as far as FR-EPDM insulated cables are concerned.

本文言語English
ホスト出版物のタイトルCMD 2016 - International Conference on Condition Monitoring and Diagnosis
出版社Institute of Electrical and Electronics Engineers Inc.
ページ36-39
ページ数4
ISBN(電子版)9781509033980
DOI
出版ステータスPublished - 2016 11 28
イベント2016 International Conference on Condition Monitoring and Diagnosis, CMD 2016 - Xi'an, China
継続期間: 2016 9 252016 9 28

Other

Other2016 International Conference on Condition Monitoring and Diagnosis, CMD 2016
CountryChina
CityXi'an
Period16/9/2516/9/28

ASJC Scopus subject areas

  • Energy Engineering and Power Technology
  • Electrical and Electronic Engineering
  • Safety, Risk, Reliability and Quality

フィンガープリント 「Fault location in a cable for a nuclear power plant by frequency domain reflectometry」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル