Field measurement on thermal comfort of patients and medical staff in a dialysis room

Hitomi Tsutsumi, Mai Fujiwara, Shinichi Tanabe, Satoshi Hori, Yoshio Shimizu, Hiroaki Io, Chieko Hamada, Yasuhiko Tomino

    研究成果: Conference contribution

    抄録

    In order to evaluate the thermal environment and comfort of patients and medical staff in a dialysis room, field measurements were conducted for five seasons (November 2010 to February 2012). The thermal environment was measured for all five seasons, and questionnaires on thermal comfort in the dialysis room were distributed to both patients and staff members. Each patient reported his/her sensations twice during each treatment session for two days in each season, whereas each staff member voted twice per day for four days in each season. According to the thermal and humidity sensations reported in the questionnaires, the comfort zones for dialysis patients and medical staff were plotted on a psychrometric chart for spring, summer, and winter.

    元の言語English
    ホスト出版物のタイトルIndoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate
    出版者International Society of Indoor Air Quality and Climate
    ページ430-437
    ページ数8
    出版物ステータスPublished - 2014
    イベント13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014 - Hong Kong
    継続期間: 2014 7 72014 7 12

    Other

    Other13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014
    Hong Kong
    期間14/7/714/7/12

    Fingerprint

    Dialysis
    Thermal comfort
    Medical Staff
    Hot Temperature
    Atmospheric humidity
    Humidity
    Patient Comfort
    Surveys and Questionnaires
    Therapeutics

    ASJC Scopus subject areas

    • Pollution
    • Building and Construction
    • Health, Toxicology and Mutagenesis
    • Computer Science Applications

    これを引用

    Tsutsumi, H., Fujiwara, M., Tanabe, S., Hori, S., Shimizu, Y., Io, H., ... Tomino, Y. (2014). Field measurement on thermal comfort of patients and medical staff in a dialysis room. : Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate (pp. 430-437). International Society of Indoor Air Quality and Climate.

    Field measurement on thermal comfort of patients and medical staff in a dialysis room. / Tsutsumi, Hitomi; Fujiwara, Mai; Tanabe, Shinichi; Hori, Satoshi; Shimizu, Yoshio; Io, Hiroaki; Hamada, Chieko; Tomino, Yasuhiko.

    Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate, 2014. p. 430-437.

    研究成果: Conference contribution

    Tsutsumi, H, Fujiwara, M, Tanabe, S, Hori, S, Shimizu, Y, Io, H, Hamada, C & Tomino, Y 2014, Field measurement on thermal comfort of patients and medical staff in a dialysis room. : Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate, pp. 430-437, 13th International Conference on Indoor Air Quality and Climate, Indoor Air 2014, Hong Kong, 14/7/7.
    Tsutsumi H, Fujiwara M, Tanabe S, Hori S, Shimizu Y, Io H その他. Field measurement on thermal comfort of patients and medical staff in a dialysis room. : Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate. 2014. p. 430-437
    Tsutsumi, Hitomi ; Fujiwara, Mai ; Tanabe, Shinichi ; Hori, Satoshi ; Shimizu, Yoshio ; Io, Hiroaki ; Hamada, Chieko ; Tomino, Yasuhiko. / Field measurement on thermal comfort of patients and medical staff in a dialysis room. Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate. International Society of Indoor Air Quality and Climate, 2014. pp. 430-437
    @inproceedings{f7cbc5814a7e4a8c8248f6b4211a572a,
    title = "Field measurement on thermal comfort of patients and medical staff in a dialysis room",
    abstract = "In order to evaluate the thermal environment and comfort of patients and medical staff in a dialysis room, field measurements were conducted for five seasons (November 2010 to February 2012). The thermal environment was measured for all five seasons, and questionnaires on thermal comfort in the dialysis room were distributed to both patients and staff members. Each patient reported his/her sensations twice during each treatment session for two days in each season, whereas each staff member voted twice per day for four days in each season. According to the thermal and humidity sensations reported in the questionnaires, the comfort zones for dialysis patients and medical staff were plotted on a psychrometric chart for spring, summer, and winter.",
    keywords = "Dialysis room, Medical staff, Patient, Thermal comfort",
    author = "Hitomi Tsutsumi and Mai Fujiwara and Shinichi Tanabe and Satoshi Hori and Yoshio Shimizu and Hiroaki Io and Chieko Hamada and Yasuhiko Tomino",
    year = "2014",
    language = "English",
    pages = "430--437",
    booktitle = "Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate",
    publisher = "International Society of Indoor Air Quality and Climate",

    }

    TY - GEN

    T1 - Field measurement on thermal comfort of patients and medical staff in a dialysis room

    AU - Tsutsumi, Hitomi

    AU - Fujiwara, Mai

    AU - Tanabe, Shinichi

    AU - Hori, Satoshi

    AU - Shimizu, Yoshio

    AU - Io, Hiroaki

    AU - Hamada, Chieko

    AU - Tomino, Yasuhiko

    PY - 2014

    Y1 - 2014

    N2 - In order to evaluate the thermal environment and comfort of patients and medical staff in a dialysis room, field measurements were conducted for five seasons (November 2010 to February 2012). The thermal environment was measured for all five seasons, and questionnaires on thermal comfort in the dialysis room were distributed to both patients and staff members. Each patient reported his/her sensations twice during each treatment session for two days in each season, whereas each staff member voted twice per day for four days in each season. According to the thermal and humidity sensations reported in the questionnaires, the comfort zones for dialysis patients and medical staff were plotted on a psychrometric chart for spring, summer, and winter.

    AB - In order to evaluate the thermal environment and comfort of patients and medical staff in a dialysis room, field measurements were conducted for five seasons (November 2010 to February 2012). The thermal environment was measured for all five seasons, and questionnaires on thermal comfort in the dialysis room were distributed to both patients and staff members. Each patient reported his/her sensations twice during each treatment session for two days in each season, whereas each staff member voted twice per day for four days in each season. According to the thermal and humidity sensations reported in the questionnaires, the comfort zones for dialysis patients and medical staff were plotted on a psychrometric chart for spring, summer, and winter.

    KW - Dialysis room

    KW - Medical staff

    KW - Patient

    KW - Thermal comfort

    UR - http://www.scopus.com/inward/record.url?scp=84924678367&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=84924678367&partnerID=8YFLogxK

    M3 - Conference contribution

    AN - SCOPUS:84924678367

    SP - 430

    EP - 437

    BT - Indoor Air 2014 - 13th International Conference on Indoor Air Quality and Climate

    PB - International Society of Indoor Air Quality and Climate

    ER -