Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2)

Masahiro Oroku, Takashi Yamanaka, Yoshio Kamiya, Taikan Suehara, Hakutaro Yoda, Sachio Komamiya, Toshiaki Tauchi, Nobuhiro Terunuma, Tatsuya Kume, Yosuke Honda

研究成果: Conference contribution

2 引用 (Scopus)

抄録

A calorimetric detector for inverse-compton photons from the Shintake monitor at the ATF2 test beam facility at KEK is developed. The Shintake monitor is the precision beam size monitor based on laser interferometer, which is planned to be used at a commissioning of the ILC beam delivery system. The detector has original structure to separate the compton signal from Bremsstrahlung background using the difference in shower development. The beam test of the detector was performed at ATF in the 2007's winter using a laser wire and a wire scanner. It was confirmed to be able to see the difference in the shower development and to separate compton photons from Bremsstrahlung photons. The beamtest plan of Shintake monitor at ATF2 on 2008's winter is also described.

元の言語English
ホスト出版物のタイトル2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
ページ2330-2334
ページ数5
DOI
出版物ステータスPublished - 2008 12 1
外部発表Yes
イベント2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008 - Dresden
継続期間: 2008 10 192008 10 25

Other

Other2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008
Dresden
期間08/10/1908/10/25

Fingerprint

Photons
monitors
detectors
Lasers
showers
bremsstrahlung
winter
photons
F-22 aircraft
wire
scanners
lasers
delivery
interferometers

ASJC Scopus subject areas

  • Radiation
  • Nuclear and High Energy Physics
  • Radiology Nuclear Medicine and imaging

これを引用

Oroku, M., Yamanaka, T., Kamiya, Y., Suehara, T., Yoda, H., Komamiya, S., ... Honda, Y. (2008). Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2). : 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008 (pp. 2330-2334). [4774824] https://doi.org/10.1109/NSSMIC.2008.4774824

Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2). / Oroku, Masahiro; Yamanaka, Takashi; Kamiya, Yoshio; Suehara, Taikan; Yoda, Hakutaro; Komamiya, Sachio; Tauchi, Toshiaki; Terunuma, Nobuhiro; Kume, Tatsuya; Honda, Yosuke.

2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008. 2008. p. 2330-2334 4774824.

研究成果: Conference contribution

Oroku, M, Yamanaka, T, Kamiya, Y, Suehara, T, Yoda, H, Komamiya, S, Tauchi, T, Terunuma, N, Kume, T & Honda, Y 2008, Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2). : 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008., 4774824, pp. 2330-2334, 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008, Dresden, 08/10/19. https://doi.org/10.1109/NSSMIC.2008.4774824
Oroku M, Yamanaka T, Kamiya Y, Suehara T, Yoda H, Komamiya S その他. Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2). : 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008. 2008. p. 2330-2334. 4774824 https://doi.org/10.1109/NSSMIC.2008.4774824
Oroku, Masahiro ; Yamanaka, Takashi ; Kamiya, Yoshio ; Suehara, Taikan ; Yoda, Hakutaro ; Komamiya, Sachio ; Tauchi, Toshiaki ; Terunuma, Nobuhiro ; Kume, Tatsuya ; Honda, Yosuke. / Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2). 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008. 2008. pp. 2330-2334
@inproceedings{b7f60206195d4d0f83fdae95f59cb08f,
title = "Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2)",
abstract = "A calorimetric detector for inverse-compton photons from the Shintake monitor at the ATF2 test beam facility at KEK is developed. The Shintake monitor is the precision beam size monitor based on laser interferometer, which is planned to be used at a commissioning of the ILC beam delivery system. The detector has original structure to separate the compton signal from Bremsstrahlung background using the difference in shower development. The beam test of the detector was performed at ATF in the 2007's winter using a laser wire and a wire scanner. It was confirmed to be able to see the difference in the shower development and to separate compton photons from Bremsstrahlung photons. The beamtest plan of Shintake monitor at ATF2 on 2008's winter is also described.",
keywords = "ATF, ATF2, Beam size monitor, Calorimeter, Detector, ILC, Inverse Compton, Shintake monitor",
author = "Masahiro Oroku and Takashi Yamanaka and Yoshio Kamiya and Taikan Suehara and Hakutaro Yoda and Sachio Komamiya and Toshiaki Tauchi and Nobuhiro Terunuma and Tatsuya Kume and Yosuke Honda",
year = "2008",
month = "12",
day = "1",
doi = "10.1109/NSSMIC.2008.4774824",
language = "English",
isbn = "9781424427154",
pages = "2330--2334",
booktitle = "2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008",

}

TY - GEN

T1 - Gamma detector for the shintake monitor (IP Beam Size Monitor at ATF2)

AU - Oroku, Masahiro

AU - Yamanaka, Takashi

AU - Kamiya, Yoshio

AU - Suehara, Taikan

AU - Yoda, Hakutaro

AU - Komamiya, Sachio

AU - Tauchi, Toshiaki

AU - Terunuma, Nobuhiro

AU - Kume, Tatsuya

AU - Honda, Yosuke

PY - 2008/12/1

Y1 - 2008/12/1

N2 - A calorimetric detector for inverse-compton photons from the Shintake monitor at the ATF2 test beam facility at KEK is developed. The Shintake monitor is the precision beam size monitor based on laser interferometer, which is planned to be used at a commissioning of the ILC beam delivery system. The detector has original structure to separate the compton signal from Bremsstrahlung background using the difference in shower development. The beam test of the detector was performed at ATF in the 2007's winter using a laser wire and a wire scanner. It was confirmed to be able to see the difference in the shower development and to separate compton photons from Bremsstrahlung photons. The beamtest plan of Shintake monitor at ATF2 on 2008's winter is also described.

AB - A calorimetric detector for inverse-compton photons from the Shintake monitor at the ATF2 test beam facility at KEK is developed. The Shintake monitor is the precision beam size monitor based on laser interferometer, which is planned to be used at a commissioning of the ILC beam delivery system. The detector has original structure to separate the compton signal from Bremsstrahlung background using the difference in shower development. The beam test of the detector was performed at ATF in the 2007's winter using a laser wire and a wire scanner. It was confirmed to be able to see the difference in the shower development and to separate compton photons from Bremsstrahlung photons. The beamtest plan of Shintake monitor at ATF2 on 2008's winter is also described.

KW - ATF

KW - ATF2

KW - Beam size monitor

KW - Calorimeter

KW - Detector

KW - ILC

KW - Inverse Compton

KW - Shintake monitor

UR - http://www.scopus.com/inward/record.url?scp=67649199893&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67649199893&partnerID=8YFLogxK

U2 - 10.1109/NSSMIC.2008.4774824

DO - 10.1109/NSSMIC.2008.4774824

M3 - Conference contribution

AN - SCOPUS:67649199893

SN - 9781424427154

SP - 2330

EP - 2334

BT - 2008 IEEE Nuclear Science Symposium Conference Record, NSS/MIC 2008

ER -