High temperature NPSH and its application for a feedwater system

Jun Manabe*, Kazuyoshi Miyagawa

*この研究の対応する著者

研究成果: Article査読

1 被引用数 (Scopus)

抄録

Eight hundred MWe class PWR turbine-generators operated smoothly and continuously at sudden load reduction from full load to house load, maintaining NPSH of the feedwater booster pumps through transition even though the available NPSH never exceeded zero. NPSH of the pump at 151.3°C, at which the available NPSH was minimal during transition, was evaluated as a slightly negative value, in spite of a positive value at room temperature, applying both the Ruggeri-Moore method extended to the negative area on condition of gas venting out of the system, using data of both room temperature and 95°C of a model pump facility, and another restriction by gas presence at the impeller inlet. The above evaluated high temperature NPSH demonstrated successful operation of the units equipped with a low static suction head yielding zero available NPSH during transition, resulting in alteration of the design criteria of the feedwater system and thereby contributing to possible cost reduction.

本文言語English
ページ(範囲)352-359
ページ数8
ジャーナルJSME International Journal, Series B: Fluids and Thermal Engineering
49
2
DOI
出版ステータスPublished - 2006 11 15
外部発表はい

ASJC Scopus subject areas

  • 機械工学
  • 物理化学および理論化学
  • 流体および伝熱

フィンガープリント

「High temperature NPSH and its application for a feedwater system」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

引用スタイル