Improvement of mass resolution for iron isotopes in CR-39 track detector

Satoshi Kodaira, Nakahiro Yasuda, Nobuyuki Hasebe, Tadayoshi Doke, Shuya Ota, Masashi Sato, Hiroko Tawara, Koichi Ogura

    研究成果: Article査読

    15 被引用数 (Scopus)

    抄録

    The capability of the CR-39 track detector for isotope identification was verified using 56Fe and 55Fe beams from the heavy ion accelerator HIMAC at NIRS. A CR-39 stack was exposed to 56Fe and 55Fe beams with the energies of 460MeV/nucleon. Drastic improvements in the accuracies of microscopic image analysis and detector thickness measurement enabled us to identify those iron isotopes with high mass resolution using the CR-39 track detector. As a consequence of the reduction of systematic errors, the mass resolution for iron isotopes in the CR-39 detector was obtained to be 0.22 ± 0.03 amu in rms. The mass resolution newly obtained by the CR-39 detector was compared with the former result and found to be 66% better than the former value of mass resolution as a result of reducing the systematic errors of mass dispersion. Moreover, the ultimate mass resolution of the CR-39 detector was estimated by calculation using those experimental results. As a consequence of reducing the random error, it is expected that the mass resolution for iron isotopes can ultimately approach to ∼0.10 amu in the CR-39 detector.

    本文言語English
    ページ(範囲)5281-5287
    ページ数7
    ジャーナルJapanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers
    46
    8 A
    DOI
    出版ステータスPublished - 2007 8 6

    ASJC Scopus subject areas

    • 物理学および天文学(その他)

    フィンガープリント

    「Improvement of mass resolution for iron isotopes in CR-39 track detector」の研究トピックを掘り下げます。これらがまとまってユニークなフィンガープリントを構成します。

    引用スタイル