Influence of refrigerant mass fraction in the performance of an ammonia absorption refrigerator

Keisuke Takeshita, Yoshiharu Amano, Takumi Hashizume, Toshitaka Takei, Masao Tomizawa

研究成果: Article

1 引用 (Scopus)

抜粋

The performance of the rectifying column affects the coefficient of performance (COP) of an ammonia absorption refrigerator. Ammonia mass fraction of refrigerant is one of the key parameters indicating the performance of the rectifying column. We propose a method to estimate the refrigerant mass fraction with mass and energy balance equations around the separator at the inlet of the evaporator, and describe the results of experiments which measured the refrigerant mass fraction by sampling from the refrigerant receiver. Throughout these investigations, the refrigerant mass fraction turned out to be lower than the expected value calculated from the condition of dry-saturated vapor at the top of the rectifying column. The refrigerant mass fraction can be estimated within an accuracy of 0.3% by the estimation method based on mass and energy balance equations.

元の言語English
ページ(範囲)242-248
ページ数7
ジャーナルJSME International Journal, Series B: Fluids and Thermal Engineering
47
発行部数2
DOI
出版物ステータスPublished - 2004 5 1

ASJC Scopus subject areas

  • Mechanical Engineering
  • Physical and Theoretical Chemistry
  • Fluid Flow and Transfer Processes

フィンガープリント Influence of refrigerant mass fraction in the performance of an ammonia absorption refrigerator' の研究トピックを掘り下げます。これらはともに一意のフィンガープリントを構成します。