Influence of stud size and stud strength of smaller spaced grouped arrangement of headed stud connectors on shear strength behavior and evaluation of shear strength of slabs

Jun Okada, Teruhiko Yoda

研究成果: Article

抄録

One of the possibilities of the efficient connection of steel-concrete composite structures is the grouped arrangement of headed stud connectors. An analytical study of the smaller spaced grouped arrangement of headed stud connectors on stud size and on stud strength is carried out and the influence of these parameters on the shear strength is investigated on the basis of the failure mode. Moreover, an estimation method of the shear strength of headed stud connectors allowing for the influence of stud size, stud strength, concrete strength, and grouped arrangement is proposed and the shear strength of the slabs close to the grouped arrangement of headed stud connectors is evaluated.

元の言語English
ページ(範囲)556-569
ページ数14
ジャーナルDoboku Gakkai Ronbunshuu A
62
発行部数3
DOI
出版物ステータスPublished - 2006
外部発表Yes

Fingerprint

Shear strength
Concretes
Composite structures
Failure modes
Steel

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Mechanics of Materials
  • Mechanical Engineering
  • Building and Construction

これを引用

@article{8ea4675a57ff48c7b6670aebedcd41da,
title = "Influence of stud size and stud strength of smaller spaced grouped arrangement of headed stud connectors on shear strength behavior and evaluation of shear strength of slabs",
abstract = "One of the possibilities of the efficient connection of steel-concrete composite structures is the grouped arrangement of headed stud connectors. An analytical study of the smaller spaced grouped arrangement of headed stud connectors on stud size and on stud strength is carried out and the influence of these parameters on the shear strength is investigated on the basis of the failure mode. Moreover, an estimation method of the shear strength of headed stud connectors allowing for the influence of stud size, stud strength, concrete strength, and grouped arrangement is proposed and the shear strength of the slabs close to the grouped arrangement of headed stud connectors is evaluated.",
keywords = "Eurocode 4, Fe-analysis, Grouped arrangement, Headed stud connector, Shear strength",
author = "Jun Okada and Teruhiko Yoda",
year = "2006",
doi = "10.2208/jsceja.62.556",
language = "English",
volume = "62",
pages = "556--569",
journal = "Doboku Gakkai Ronbunshuu A",
issn = "1880-6023",
publisher = "Japan Society of Civil Engineers",
number = "3",

}

TY - JOUR

T1 - Influence of stud size and stud strength of smaller spaced grouped arrangement of headed stud connectors on shear strength behavior and evaluation of shear strength of slabs

AU - Okada, Jun

AU - Yoda, Teruhiko

PY - 2006

Y1 - 2006

N2 - One of the possibilities of the efficient connection of steel-concrete composite structures is the grouped arrangement of headed stud connectors. An analytical study of the smaller spaced grouped arrangement of headed stud connectors on stud size and on stud strength is carried out and the influence of these parameters on the shear strength is investigated on the basis of the failure mode. Moreover, an estimation method of the shear strength of headed stud connectors allowing for the influence of stud size, stud strength, concrete strength, and grouped arrangement is proposed and the shear strength of the slabs close to the grouped arrangement of headed stud connectors is evaluated.

AB - One of the possibilities of the efficient connection of steel-concrete composite structures is the grouped arrangement of headed stud connectors. An analytical study of the smaller spaced grouped arrangement of headed stud connectors on stud size and on stud strength is carried out and the influence of these parameters on the shear strength is investigated on the basis of the failure mode. Moreover, an estimation method of the shear strength of headed stud connectors allowing for the influence of stud size, stud strength, concrete strength, and grouped arrangement is proposed and the shear strength of the slabs close to the grouped arrangement of headed stud connectors is evaluated.

KW - Eurocode 4

KW - Fe-analysis

KW - Grouped arrangement

KW - Headed stud connector

KW - Shear strength

UR - http://www.scopus.com/inward/record.url?scp=79954440088&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79954440088&partnerID=8YFLogxK

U2 - 10.2208/jsceja.62.556

DO - 10.2208/jsceja.62.556

M3 - Article

AN - SCOPUS:79954440088

VL - 62

SP - 556

EP - 569

JO - Doboku Gakkai Ronbunshuu A

JF - Doboku Gakkai Ronbunshuu A

SN - 1880-6023

IS - 3

ER -