Investigating accuracy of tilting operation on wrist-worn devices with touchscreens

Keigo Shima, Kazusa Onishi, Ryosuke Takada, Takuya Adachi, Buntarou Shizuki, Jiro Tanaka

研究成果: Conference contribution

5 引用 (Scopus)

抄録

The tilting operation has been shown to be useful in expanding the input vocabulary of a small device; therefore, this operation could also be useful in expanding the input vocabulary of wrist-worn devices. In this study, in order to explore new design guidelines of GUI and operation methods for smartwatches, we have investigated the accuracy of the tilting operation for smartwatches. We conducted an experiment using a cursor whose position is determined according to the direction and angle of tilt. The result shows that the deviation in the x-axis (i.e., the inclination of the arm) direction ranges from -0.10 degrees to +0.07 degrees and from -0.10 degrees to +0.07 degrees under Seating and Standing condition, respectively; the deviation in the y-axis (i.e., the rotation of the wrist) direction from -0.12 degrees to +0.10 degrees and from -0.12 degrees to +0.09 degrees.

元の言語English
ホスト出版物のタイトルCHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems
出版者Association for Computing Machinery
ページ2705-2711
ページ数7
07-12-May-2016
ISBN(電子版)9781450340823
DOI
出版物ステータスPublished - 2016 5 7
外部発表Yes
イベント34th Annual CHI Conference on Human Factors in Computing Systems, CHI EA 2016 - San Jose, United States
継続期間: 2016 5 72016 5 12

Other

Other34th Annual CHI Conference on Human Factors in Computing Systems, CHI EA 2016
United States
San Jose
期間16/5/716/5/12

Fingerprint

Touch screens
Graphical user interfaces
Experiments

ASJC Scopus subject areas

  • Human-Computer Interaction
  • Computer Graphics and Computer-Aided Design
  • Software

これを引用

Shima, K., Onishi, K., Takada, R., Adachi, T., Shizuki, B., & Tanaka, J. (2016). Investigating accuracy of tilting operation on wrist-worn devices with touchscreens. : CHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems (巻 07-12-May-2016, pp. 2705-2711). Association for Computing Machinery. https://doi.org/10.1145/2851581.2892377

Investigating accuracy of tilting operation on wrist-worn devices with touchscreens. / Shima, Keigo; Onishi, Kazusa; Takada, Ryosuke; Adachi, Takuya; Shizuki, Buntarou; Tanaka, Jiro.

CHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems. 巻 07-12-May-2016 Association for Computing Machinery, 2016. p. 2705-2711.

研究成果: Conference contribution

Shima, K, Onishi, K, Takada, R, Adachi, T, Shizuki, B & Tanaka, J 2016, Investigating accuracy of tilting operation on wrist-worn devices with touchscreens. : CHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems. 巻. 07-12-May-2016, Association for Computing Machinery, pp. 2705-2711, 34th Annual CHI Conference on Human Factors in Computing Systems, CHI EA 2016, San Jose, United States, 16/5/7. https://doi.org/10.1145/2851581.2892377
Shima K, Onishi K, Takada R, Adachi T, Shizuki B, Tanaka J. Investigating accuracy of tilting operation on wrist-worn devices with touchscreens. : CHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems. 巻 07-12-May-2016. Association for Computing Machinery. 2016. p. 2705-2711 https://doi.org/10.1145/2851581.2892377
Shima, Keigo ; Onishi, Kazusa ; Takada, Ryosuke ; Adachi, Takuya ; Shizuki, Buntarou ; Tanaka, Jiro. / Investigating accuracy of tilting operation on wrist-worn devices with touchscreens. CHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems. 巻 07-12-May-2016 Association for Computing Machinery, 2016. pp. 2705-2711
@inproceedings{9fc9405f942c45969100fb242b9a854f,
title = "Investigating accuracy of tilting operation on wrist-worn devices with touchscreens",
abstract = "The tilting operation has been shown to be useful in expanding the input vocabulary of a small device; therefore, this operation could also be useful in expanding the input vocabulary of wrist-worn devices. In this study, in order to explore new design guidelines of GUI and operation methods for smartwatches, we have investigated the accuracy of the tilting operation for smartwatches. We conducted an experiment using a cursor whose position is determined according to the direction and angle of tilt. The result shows that the deviation in the x-axis (i.e., the inclination of the arm) direction ranges from -0.10 degrees to +0.07 degrees and from -0.10 degrees to +0.07 degrees under Seating and Standing condition, respectively; the deviation in the y-axis (i.e., the rotation of the wrist) direction from -0.12 degrees to +0.10 degrees and from -0.12 degrees to +0.09 degrees.",
keywords = "Cursor, Motor skill, Pointing, Smartwatch, Target acquisition accuracy",
author = "Keigo Shima and Kazusa Onishi and Ryosuke Takada and Takuya Adachi and Buntarou Shizuki and Jiro Tanaka",
year = "2016",
month = "5",
day = "7",
doi = "10.1145/2851581.2892377",
language = "English",
volume = "07-12-May-2016",
pages = "2705--2711",
booktitle = "CHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems",
publisher = "Association for Computing Machinery",

}

TY - GEN

T1 - Investigating accuracy of tilting operation on wrist-worn devices with touchscreens

AU - Shima, Keigo

AU - Onishi, Kazusa

AU - Takada, Ryosuke

AU - Adachi, Takuya

AU - Shizuki, Buntarou

AU - Tanaka, Jiro

PY - 2016/5/7

Y1 - 2016/5/7

N2 - The tilting operation has been shown to be useful in expanding the input vocabulary of a small device; therefore, this operation could also be useful in expanding the input vocabulary of wrist-worn devices. In this study, in order to explore new design guidelines of GUI and operation methods for smartwatches, we have investigated the accuracy of the tilting operation for smartwatches. We conducted an experiment using a cursor whose position is determined according to the direction and angle of tilt. The result shows that the deviation in the x-axis (i.e., the inclination of the arm) direction ranges from -0.10 degrees to +0.07 degrees and from -0.10 degrees to +0.07 degrees under Seating and Standing condition, respectively; the deviation in the y-axis (i.e., the rotation of the wrist) direction from -0.12 degrees to +0.10 degrees and from -0.12 degrees to +0.09 degrees.

AB - The tilting operation has been shown to be useful in expanding the input vocabulary of a small device; therefore, this operation could also be useful in expanding the input vocabulary of wrist-worn devices. In this study, in order to explore new design guidelines of GUI and operation methods for smartwatches, we have investigated the accuracy of the tilting operation for smartwatches. We conducted an experiment using a cursor whose position is determined according to the direction and angle of tilt. The result shows that the deviation in the x-axis (i.e., the inclination of the arm) direction ranges from -0.10 degrees to +0.07 degrees and from -0.10 degrees to +0.07 degrees under Seating and Standing condition, respectively; the deviation in the y-axis (i.e., the rotation of the wrist) direction from -0.12 degrees to +0.10 degrees and from -0.12 degrees to +0.09 degrees.

KW - Cursor

KW - Motor skill

KW - Pointing

KW - Smartwatch

KW - Target acquisition accuracy

UR - http://www.scopus.com/inward/record.url?scp=85014659028&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85014659028&partnerID=8YFLogxK

U2 - 10.1145/2851581.2892377

DO - 10.1145/2851581.2892377

M3 - Conference contribution

AN - SCOPUS:85014659028

VL - 07-12-May-2016

SP - 2705

EP - 2711

BT - CHI EA 2016: #chi4good - Extended Abstracts, 34th Annual CHI Conference on Human Factors in Computing Systems

PB - Association for Computing Machinery

ER -