Load-bearing pattern of the ankle joint - Contact Area and Pressure Distribution

Mamori Kimizuka, Hisashi Kurosawa, Toru Fukubayashi

研究成果: Article

102 引用 (Scopus)

抄録

The contact area of eight human talocrural joints was measured. After preparation, the talocrural joint was set into the compression machine. Under loading the casting was made by silicon rubber and the pressure distribution was measured by pressure sensor sheet. The contact area was localized at anterior and lateral parts. Under 1,500 N loading, the contact area was 522 mm2 and the maximum pressure was 9.9 MPa. Slight diastasis caused a decrease of the contact area and an increase of pressure.

元の言語English
ページ(範囲)45-49
ページ数5
ジャーナルArchives of Orthopaedic and Traumatic Surgery
96
発行部数1
DOI
出版物ステータスPublished - 1980 3
外部発表Yes

Fingerprint

Ankle Joint
Weight-Bearing
Pressure
Joints
Rubber
Silicon

ASJC Scopus subject areas

  • Surgery

これを引用

Load-bearing pattern of the ankle joint - Contact Area and Pressure Distribution. / Kimizuka, Mamori; Kurosawa, Hisashi; Fukubayashi, Toru.

:: Archives of Orthopaedic and Traumatic Surgery, 巻 96, 番号 1, 03.1980, p. 45-49.

研究成果: Article

Kimizuka, Mamori ; Kurosawa, Hisashi ; Fukubayashi, Toru. / Load-bearing pattern of the ankle joint - Contact Area and Pressure Distribution. :: Archives of Orthopaedic and Traumatic Surgery. 1980 ; 巻 96, 番号 1. pp. 45-49.
@article{e8f86f4b0d5e4c729592914f1654b552,
title = "Load-bearing pattern of the ankle joint - Contact Area and Pressure Distribution",
abstract = "The contact area of eight human talocrural joints was measured. After preparation, the talocrural joint was set into the compression machine. Under loading the casting was made by silicon rubber and the pressure distribution was measured by pressure sensor sheet. The contact area was localized at anterior and lateral parts. Under 1,500 N loading, the contact area was 522 mm2 and the maximum pressure was 9.9 MPa. Slight diastasis caused a decrease of the contact area and an increase of pressure.",
author = "Mamori Kimizuka and Hisashi Kurosawa and Toru Fukubayashi",
year = "1980",
month = "3",
doi = "10.1007/BF01246141",
language = "English",
volume = "96",
pages = "45--49",
journal = "Archives of Orthopaedic and Trauma Surgery",
issn = "0936-8051",
publisher = "Springer Verlag",
number = "1",

}

TY - JOUR

T1 - Load-bearing pattern of the ankle joint - Contact Area and Pressure Distribution

AU - Kimizuka, Mamori

AU - Kurosawa, Hisashi

AU - Fukubayashi, Toru

PY - 1980/3

Y1 - 1980/3

N2 - The contact area of eight human talocrural joints was measured. After preparation, the talocrural joint was set into the compression machine. Under loading the casting was made by silicon rubber and the pressure distribution was measured by pressure sensor sheet. The contact area was localized at anterior and lateral parts. Under 1,500 N loading, the contact area was 522 mm2 and the maximum pressure was 9.9 MPa. Slight diastasis caused a decrease of the contact area and an increase of pressure.

AB - The contact area of eight human talocrural joints was measured. After preparation, the talocrural joint was set into the compression machine. Under loading the casting was made by silicon rubber and the pressure distribution was measured by pressure sensor sheet. The contact area was localized at anterior and lateral parts. Under 1,500 N loading, the contact area was 522 mm2 and the maximum pressure was 9.9 MPa. Slight diastasis caused a decrease of the contact area and an increase of pressure.

UR - http://www.scopus.com/inward/record.url?scp=0018844822&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018844822&partnerID=8YFLogxK

U2 - 10.1007/BF01246141

DO - 10.1007/BF01246141

M3 - Article

VL - 96

SP - 45

EP - 49

JO - Archives of Orthopaedic and Trauma Surgery

JF - Archives of Orthopaedic and Trauma Surgery

SN - 0936-8051

IS - 1

ER -