In this letter, a method to maximize the operation time, even in cases of longer power interruption, by minimizing the power lost by the load is developed using the Lagrange function.

元の言語English
ページ(範囲)268-269
ページ数2
ジャーナルIEEJ Journal of Industry Applications
7
発行部数3
DOI
出版物ステータスPublished - 2018 1 1
外部発表Yes

Fingerprint

Compressors
Air

ASJC Scopus subject areas

  • Automotive Engineering
  • Energy Engineering and Power Technology
  • Mechanical Engineering
  • Industrial and Manufacturing Engineering
  • Electrical and Electronic Engineering

これを引用

@article{921a7a0409804b6f9d930c2e6b9e8271,
title = "Maximum continuous operation time control of PMSM with compressor loads of air conditioners under DC power supply loss",
abstract = "In this letter, a method to maximize the operation time, even in cases of longer power interruption, by minimizing the power lost by the load is developed using the Lagrange function.",
keywords = "Continuous operation, Low inertial loads, PMSM, Power supply loss",
author = "Jongwon Heo and Keiichiro Kondo",
year = "2018",
month = "1",
day = "1",
doi = "10.1541/ieejjia.7.268",
language = "English",
volume = "7",
pages = "268--269",
journal = "IEEJ Journal of Industry Applications",
issn = "2187-1094",
publisher = "The Institute of Electrical Engineers of Japan",
number = "3",

}

TY - JOUR

T1 - Maximum continuous operation time control of PMSM with compressor loads of air conditioners under DC power supply loss

AU - Heo, Jongwon

AU - Kondo, Keiichiro

PY - 2018/1/1

Y1 - 2018/1/1

N2 - In this letter, a method to maximize the operation time, even in cases of longer power interruption, by minimizing the power lost by the load is developed using the Lagrange function.

AB - In this letter, a method to maximize the operation time, even in cases of longer power interruption, by minimizing the power lost by the load is developed using the Lagrange function.

KW - Continuous operation

KW - Low inertial loads

KW - PMSM

KW - Power supply loss

UR - http://www.scopus.com/inward/record.url?scp=85046271701&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85046271701&partnerID=8YFLogxK

U2 - 10.1541/ieejjia.7.268

DO - 10.1541/ieejjia.7.268

M3 - Article

AN - SCOPUS:85046271701

VL - 7

SP - 268

EP - 269

JO - IEEJ Journal of Industry Applications

JF - IEEJ Journal of Industry Applications

SN - 2187-1094

IS - 3

ER -