Measurement of cough droplet deposition using the cough machine

Masayuki Ogata, Maho Ichikawa, Hitomi Tsutsumi, Takao Ariga, Satoshi Hori, Shinichi Tanabe

    研究成果: Article

    1 引用 (Scopus)

    抄録

    We developed a cough machine that can generate human-like cough to evaluate the infection risk in indoor environments. The cough expired volume, propagation distance and velocity of cough, total mass of droplets and droplet size were compared with experimental results of subjects. Using the cough machine, the droplet deposition on horizontal surfaces and the position of facial mucous membranes were measured. It was shown that the number of droplet deposited on the facial mucous membranes decreased drastically over 90 cm. On horizontal surfaces, the droplet deposited most at 50-60 cm and over 90% of the droplet deposited within 90 cm.

    元の言語English
    ページ(範囲)57-64
    ページ数8
    ジャーナルJournal of Environmental Engineering (Japan)
    83
    発行部数743
    DOI
    出版物ステータスPublished - 2018 1 1

    Fingerprint

    Mucous Membrane

    ASJC Scopus subject areas

    • Environmental Engineering

    これを引用

    Measurement of cough droplet deposition using the cough machine. / Ogata, Masayuki; Ichikawa, Maho; Tsutsumi, Hitomi; Ariga, Takao; Hori, Satoshi; Tanabe, Shinichi.

    :: Journal of Environmental Engineering (Japan), 巻 83, 番号 743, 01.01.2018, p. 57-64.

    研究成果: Article

    Ogata, Masayuki ; Ichikawa, Maho ; Tsutsumi, Hitomi ; Ariga, Takao ; Hori, Satoshi ; Tanabe, Shinichi. / Measurement of cough droplet deposition using the cough machine. :: Journal of Environmental Engineering (Japan). 2018 ; 巻 83, 番号 743. pp. 57-64.
    @article{932a35450a934bae8100e98273e1b535,
    title = "Measurement of cough droplet deposition using the cough machine",
    abstract = "We developed a cough machine that can generate human-like cough to evaluate the infection risk in indoor environments. The cough expired volume, propagation distance and velocity of cough, total mass of droplets and droplet size were compared with experimental results of subjects. Using the cough machine, the droplet deposition on horizontal surfaces and the position of facial mucous membranes were measured. It was shown that the number of droplet deposited on the facial mucous membranes decreased drastically over 90 cm. On horizontal surfaces, the droplet deposited most at 50-60 cm and over 90{\%} of the droplet deposited within 90 cm.",
    keywords = "Contact infection, Cough-machine, Droplet infection, Infection risk depostion",
    author = "Masayuki Ogata and Maho Ichikawa and Hitomi Tsutsumi and Takao Ariga and Satoshi Hori and Shinichi Tanabe",
    year = "2018",
    month = "1",
    day = "1",
    doi = "10.3130/aije.83.57",
    language = "English",
    volume = "83",
    pages = "57--64",
    journal = "Journal of Environmental Engineering, ASCE",
    issn = "1348-0685",
    publisher = "American Society of Civil Engineers (ASCE)",
    number = "743",

    }

    TY - JOUR

    T1 - Measurement of cough droplet deposition using the cough machine

    AU - Ogata, Masayuki

    AU - Ichikawa, Maho

    AU - Tsutsumi, Hitomi

    AU - Ariga, Takao

    AU - Hori, Satoshi

    AU - Tanabe, Shinichi

    PY - 2018/1/1

    Y1 - 2018/1/1

    N2 - We developed a cough machine that can generate human-like cough to evaluate the infection risk in indoor environments. The cough expired volume, propagation distance and velocity of cough, total mass of droplets and droplet size were compared with experimental results of subjects. Using the cough machine, the droplet deposition on horizontal surfaces and the position of facial mucous membranes were measured. It was shown that the number of droplet deposited on the facial mucous membranes decreased drastically over 90 cm. On horizontal surfaces, the droplet deposited most at 50-60 cm and over 90% of the droplet deposited within 90 cm.

    AB - We developed a cough machine that can generate human-like cough to evaluate the infection risk in indoor environments. The cough expired volume, propagation distance and velocity of cough, total mass of droplets and droplet size were compared with experimental results of subjects. Using the cough machine, the droplet deposition on horizontal surfaces and the position of facial mucous membranes were measured. It was shown that the number of droplet deposited on the facial mucous membranes decreased drastically over 90 cm. On horizontal surfaces, the droplet deposited most at 50-60 cm and over 90% of the droplet deposited within 90 cm.

    KW - Contact infection

    KW - Cough-machine

    KW - Droplet infection

    KW - Infection risk depostion

    UR - http://www.scopus.com/inward/record.url?scp=85041188095&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=85041188095&partnerID=8YFLogxK

    U2 - 10.3130/aije.83.57

    DO - 10.3130/aije.83.57

    M3 - Article

    AN - SCOPUS:85041188095

    VL - 83

    SP - 57

    EP - 64

    JO - Journal of Environmental Engineering, ASCE

    JF - Journal of Environmental Engineering, ASCE

    SN - 1348-0685

    IS - 743

    ER -