Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector

Seiji Takechi, Toshiyuki Onishi, Shigeyuki Minami, Takashi Miyachi, Masayuki Fujii, Nobuyuki Hasebe, Ken Ichi Nogami, Hideo Ohashi, Sho Sasaki, Hiromi Shibata, Takeo Iwai, Eberhard Grün, Ralf Srama, Nagaya Okada

    研究成果: Article

    1 引用 (Scopus)

    抄録

    A cosmic dust detector for use onboard a satellite is currently being developed by using piezoelectric lead zirconate titanate (PZT). The characteristics of the PZT detector have been studied by bombarding it with hypervelocity iron (Fe) particles supplied by a Van de Graaff accelerator. One central electrode and four peripheral electrodes were placed on the front surface of the PZT detector to measure the impact positions of the incident Fe particles. It was demonstrated that the point of impact on the PZT detector could be identified by using information on the time at which the first peak of the output signal obtained from each electrode appeared.

    元の言語English
    記事番号043303
    ジャーナルReview of Scientific Instruments
    79
    発行部数4
    DOI
    出版物ステータスPublished - 2008

    Fingerprint

    hypervelocity
    Particles (particulate matter)
    Lead
    Detectors
    detectors
    Electrodes
    electrodes
    Van de Graaff accelerators
    cosmic dust
    Dust
    Satellites
    Iron
    iron
    output

    ASJC Scopus subject areas

    • Instrumentation
    • Physics and Astronomy (miscellaneous)

    これを引用

    Takechi, S., Onishi, T., Minami, S., Miyachi, T., Fujii, M., Hasebe, N., ... Okada, N. (2008). Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector. Review of Scientific Instruments, 79(4), [043303]. https://doi.org/10.1063/1.2908206

    Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector. / Takechi, Seiji; Onishi, Toshiyuki; Minami, Shigeyuki; Miyachi, Takashi; Fujii, Masayuki; Hasebe, Nobuyuki; Nogami, Ken Ichi; Ohashi, Hideo; Sasaki, Sho; Shibata, Hiromi; Iwai, Takeo; Grün, Eberhard; Srama, Ralf; Okada, Nagaya.

    :: Review of Scientific Instruments, 巻 79, 番号 4, 043303, 2008.

    研究成果: Article

    Takechi, S, Onishi, T, Minami, S, Miyachi, T, Fujii, M, Hasebe, N, Nogami, KI, Ohashi, H, Sasaki, S, Shibata, H, Iwai, T, Grün, E, Srama, R & Okada, N 2008, 'Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector', Review of Scientific Instruments, 巻. 79, 番号 4, 043303. https://doi.org/10.1063/1.2908206
    Takechi, Seiji ; Onishi, Toshiyuki ; Minami, Shigeyuki ; Miyachi, Takashi ; Fujii, Masayuki ; Hasebe, Nobuyuki ; Nogami, Ken Ichi ; Ohashi, Hideo ; Sasaki, Sho ; Shibata, Hiromi ; Iwai, Takeo ; Grün, Eberhard ; Srama, Ralf ; Okada, Nagaya. / Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector. :: Review of Scientific Instruments. 2008 ; 巻 79, 番号 4.
    @article{22c7425e48f84059a41c3903df228db8,
    title = "Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector",
    abstract = "A cosmic dust detector for use onboard a satellite is currently being developed by using piezoelectric lead zirconate titanate (PZT). The characteristics of the PZT detector have been studied by bombarding it with hypervelocity iron (Fe) particles supplied by a Van de Graaff accelerator. One central electrode and four peripheral electrodes were placed on the front surface of the PZT detector to measure the impact positions of the incident Fe particles. It was demonstrated that the point of impact on the PZT detector could be identified by using information on the time at which the first peak of the output signal obtained from each electrode appeared.",
    author = "Seiji Takechi and Toshiyuki Onishi and Shigeyuki Minami and Takashi Miyachi and Masayuki Fujii and Nobuyuki Hasebe and Nogami, {Ken Ichi} and Hideo Ohashi and Sho Sasaki and Hiromi Shibata and Takeo Iwai and Eberhard Gr{\"u}n and Ralf Srama and Nagaya Okada",
    year = "2008",
    doi = "10.1063/1.2908206",
    language = "English",
    volume = "79",
    journal = "Review of Scientific Instruments",
    issn = "0034-6748",
    publisher = "American Institute of Physics Publising LLC",
    number = "4",

    }

    TY - JOUR

    T1 - Measurement of incident position of hypervelocity particles on piezoelectric lead zirconate titanate detector

    AU - Takechi, Seiji

    AU - Onishi, Toshiyuki

    AU - Minami, Shigeyuki

    AU - Miyachi, Takashi

    AU - Fujii, Masayuki

    AU - Hasebe, Nobuyuki

    AU - Nogami, Ken Ichi

    AU - Ohashi, Hideo

    AU - Sasaki, Sho

    AU - Shibata, Hiromi

    AU - Iwai, Takeo

    AU - Grün, Eberhard

    AU - Srama, Ralf

    AU - Okada, Nagaya

    PY - 2008

    Y1 - 2008

    N2 - A cosmic dust detector for use onboard a satellite is currently being developed by using piezoelectric lead zirconate titanate (PZT). The characteristics of the PZT detector have been studied by bombarding it with hypervelocity iron (Fe) particles supplied by a Van de Graaff accelerator. One central electrode and four peripheral electrodes were placed on the front surface of the PZT detector to measure the impact positions of the incident Fe particles. It was demonstrated that the point of impact on the PZT detector could be identified by using information on the time at which the first peak of the output signal obtained from each electrode appeared.

    AB - A cosmic dust detector for use onboard a satellite is currently being developed by using piezoelectric lead zirconate titanate (PZT). The characteristics of the PZT detector have been studied by bombarding it with hypervelocity iron (Fe) particles supplied by a Van de Graaff accelerator. One central electrode and four peripheral electrodes were placed on the front surface of the PZT detector to measure the impact positions of the incident Fe particles. It was demonstrated that the point of impact on the PZT detector could be identified by using information on the time at which the first peak of the output signal obtained from each electrode appeared.

    UR - http://www.scopus.com/inward/record.url?scp=42949158873&partnerID=8YFLogxK

    UR - http://www.scopus.com/inward/citedby.url?scp=42949158873&partnerID=8YFLogxK

    U2 - 10.1063/1.2908206

    DO - 10.1063/1.2908206

    M3 - Article

    C2 - 18447524

    AN - SCOPUS:42949158873

    VL - 79

    JO - Review of Scientific Instruments

    JF - Review of Scientific Instruments

    SN - 0034-6748

    IS - 4

    M1 - 043303

    ER -