Method for determining line drop compensator parameters of low voltage regulator using support vector machine

Hiroshi Kikusato, Naoyuki Takahashi, Jun Yoshinaga, Yu Fujimoto, Yasuhiro Hayashi, Shinichi Kusagawa, Noriyuki Motegi

研究成果: Conference contribution

2 引用 (Scopus)

抄録

Highly accurate predictions of load demand and photovoltaic (PV) output have become possible in recent years because of improved measuring instruments and the increase of databases on load demand and PV output. The appropriate control parameters for actual power system operation can be determined by using these predictions. Although parameters determined by conventional methods are accurate, they may not be determined in time before the beginning of operation because extensive time is required for the calculations. In this paper, the support vector machine - a machine learning method that solves the two-class classification problem - is used to determine the line drop compensator (LDC) parameters instantly. To verify the validity of the proposed method, we carried out numerical simulations to determine the LDC parameters. From the simulated results, we found that the proposed method can instantly and accurately determine the LDC parameters.

元の言語English
ホスト出版物のタイトル2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014
出版者IEEE Computer Society
ISBN(印刷物)9781479936526
DOI
出版物ステータスPublished - 2014
イベント2014 IEEE Power and Energy Society Innovative Smart Grid Technologies Conference, ISGT 2014 - Washington, DC
継続期間: 2014 2 192014 2 22

Other

Other2014 IEEE Power and Energy Society Innovative Smart Grid Technologies Conference, ISGT 2014
Washington, DC
期間14/2/1914/2/22

Fingerprint

Voltage regulators
Support vector machines
Learning systems
Computer simulation

ASJC Scopus subject areas

  • Artificial Intelligence
  • Computer Networks and Communications

これを引用

Kikusato, H., Takahashi, N., Yoshinaga, J., Fujimoto, Y., Hayashi, Y., Kusagawa, S., & Motegi, N. (2014). Method for determining line drop compensator parameters of low voltage regulator using support vector machine. : 2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014 [6816413] IEEE Computer Society. https://doi.org/10.1109/ISGT.2014.6816413

Method for determining line drop compensator parameters of low voltage regulator using support vector machine. / Kikusato, Hiroshi; Takahashi, Naoyuki; Yoshinaga, Jun; Fujimoto, Yu; Hayashi, Yasuhiro; Kusagawa, Shinichi; Motegi, Noriyuki.

2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014. IEEE Computer Society, 2014. 6816413.

研究成果: Conference contribution

Kikusato, H, Takahashi, N, Yoshinaga, J, Fujimoto, Y, Hayashi, Y, Kusagawa, S & Motegi, N 2014, Method for determining line drop compensator parameters of low voltage regulator using support vector machine. : 2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014., 6816413, IEEE Computer Society, 2014 IEEE Power and Energy Society Innovative Smart Grid Technologies Conference, ISGT 2014, Washington, DC, 14/2/19. https://doi.org/10.1109/ISGT.2014.6816413
Kikusato H, Takahashi N, Yoshinaga J, Fujimoto Y, Hayashi Y, Kusagawa S その他. Method for determining line drop compensator parameters of low voltage regulator using support vector machine. : 2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014. IEEE Computer Society. 2014. 6816413 https://doi.org/10.1109/ISGT.2014.6816413
Kikusato, Hiroshi ; Takahashi, Naoyuki ; Yoshinaga, Jun ; Fujimoto, Yu ; Hayashi, Yasuhiro ; Kusagawa, Shinichi ; Motegi, Noriyuki. / Method for determining line drop compensator parameters of low voltage regulator using support vector machine. 2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014. IEEE Computer Society, 2014.
@inproceedings{aaa2763fbd92443184ff18f4f51cc3c7,
title = "Method for determining line drop compensator parameters of low voltage regulator using support vector machine",
abstract = "Highly accurate predictions of load demand and photovoltaic (PV) output have become possible in recent years because of improved measuring instruments and the increase of databases on load demand and PV output. The appropriate control parameters for actual power system operation can be determined by using these predictions. Although parameters determined by conventional methods are accurate, they may not be determined in time before the beginning of operation because extensive time is required for the calculations. In this paper, the support vector machine - a machine learning method that solves the two-class classification problem - is used to determine the line drop compensator (LDC) parameters instantly. To verify the validity of the proposed method, we carried out numerical simulations to determine the LDC parameters. From the simulated results, we found that the proposed method can instantly and accurately determine the LDC parameters.",
keywords = "Distribution systems, LDC method, LVR, SVM, Voltage control",
author = "Hiroshi Kikusato and Naoyuki Takahashi and Jun Yoshinaga and Yu Fujimoto and Yasuhiro Hayashi and Shinichi Kusagawa and Noriyuki Motegi",
year = "2014",
doi = "10.1109/ISGT.2014.6816413",
language = "English",
isbn = "9781479936526",
booktitle = "2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014",
publisher = "IEEE Computer Society",

}

TY - GEN

T1 - Method for determining line drop compensator parameters of low voltage regulator using support vector machine

AU - Kikusato, Hiroshi

AU - Takahashi, Naoyuki

AU - Yoshinaga, Jun

AU - Fujimoto, Yu

AU - Hayashi, Yasuhiro

AU - Kusagawa, Shinichi

AU - Motegi, Noriyuki

PY - 2014

Y1 - 2014

N2 - Highly accurate predictions of load demand and photovoltaic (PV) output have become possible in recent years because of improved measuring instruments and the increase of databases on load demand and PV output. The appropriate control parameters for actual power system operation can be determined by using these predictions. Although parameters determined by conventional methods are accurate, they may not be determined in time before the beginning of operation because extensive time is required for the calculations. In this paper, the support vector machine - a machine learning method that solves the two-class classification problem - is used to determine the line drop compensator (LDC) parameters instantly. To verify the validity of the proposed method, we carried out numerical simulations to determine the LDC parameters. From the simulated results, we found that the proposed method can instantly and accurately determine the LDC parameters.

AB - Highly accurate predictions of load demand and photovoltaic (PV) output have become possible in recent years because of improved measuring instruments and the increase of databases on load demand and PV output. The appropriate control parameters for actual power system operation can be determined by using these predictions. Although parameters determined by conventional methods are accurate, they may not be determined in time before the beginning of operation because extensive time is required for the calculations. In this paper, the support vector machine - a machine learning method that solves the two-class classification problem - is used to determine the line drop compensator (LDC) parameters instantly. To verify the validity of the proposed method, we carried out numerical simulations to determine the LDC parameters. From the simulated results, we found that the proposed method can instantly and accurately determine the LDC parameters.

KW - Distribution systems

KW - LDC method

KW - LVR

KW - SVM

KW - Voltage control

UR - http://www.scopus.com/inward/record.url?scp=84901946781&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84901946781&partnerID=8YFLogxK

U2 - 10.1109/ISGT.2014.6816413

DO - 10.1109/ISGT.2014.6816413

M3 - Conference contribution

AN - SCOPUS:84901946781

SN - 9781479936526

BT - 2014 IEEE PES Innovative Smart Grid Technologies Conference, ISGT 2014

PB - IEEE Computer Society

ER -