Microbioassay of nystatin with a yeast electrode

Isao Karube, Tadashi Matsunaga, Shuichi Suzuki

研究成果: Article

44 引用 (Scopus)

抜粋

Microbioassay of nystatin is achieved with an electrode composed of a yeast membrane and an oxygen electrode, based on the inhibitory action of the antibiotic on the respiration of the yeast. A linear relationship is obtained between the rate of current increase and the potency of nystatin. The minimum measurable nystatin concentration is 0.5 unit ml-1.The assay takes less than l h; the standard deviation is 1.2 unit ml-1 at the 27 USP unit ml-1 level.

元の言語English
ページ(範囲)39-44
ページ数6
ジャーナルAnalytica Chimica Acta
109
発行部数1
DOI
出版物ステータスPublished - 1979 8 1
外部発表Yes

    フィンガープリント

ASJC Scopus subject areas

  • Biochemistry
  • Analytical Chemistry
  • Spectroscopy
  • Environmental Chemistry

これを引用