Microscopic velocimetry with a scaled-up model for evaluating a flow field over cultured endothelial cells

Shuichiro Fukushima, Takaaki Deguchi, Makoto Kaibara, Kotaro Oka, Kazuo Tanishita

研究成果: Article

3 引用 (Scopus)

抄録

A microscopic velocimetry technique for evaluating the flow field over cultured endothelial cells was developed. Flow around a cell model scaled up by a factor of 100 was visualized by using an optical microscope and was quantified by using particle-tracking velocimetry. Wall shear stress on the model surface was determined from a two-dimensional velocity field interpolated from measured velocity vectors. Accuracy of the velocimetry was verified by measuring the flow over a sinusoidal cell model that had a wall shear stress profile analytically determined with linear perturbation theory. Comparison of the experimental results with the analytical solution revealed that the total error of the measured wall shear stress was 6 percent.

元の言語English
ページ(範囲)176-179
ページ数4
ジャーナルJournal of Biomechanical Engineering
124
発行部数2
DOI
出版物ステータスPublished - 2002
外部発表Yes

Fingerprint

Rheology
Endothelial cells
Velocity measurement
Shear stress
Cultured Cells
Flow fields
Endothelial Cells
Microscopes

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biophysics

これを引用

Microscopic velocimetry with a scaled-up model for evaluating a flow field over cultured endothelial cells. / Fukushima, Shuichiro; Deguchi, Takaaki; Kaibara, Makoto; Oka, Kotaro; Tanishita, Kazuo.

:: Journal of Biomechanical Engineering, 巻 124, 番号 2, 2002, p. 176-179.

研究成果: Article

Fukushima, Shuichiro ; Deguchi, Takaaki ; Kaibara, Makoto ; Oka, Kotaro ; Tanishita, Kazuo. / Microscopic velocimetry with a scaled-up model for evaluating a flow field over cultured endothelial cells. :: Journal of Biomechanical Engineering. 2002 ; 巻 124, 番号 2. pp. 176-179.
@article{840629f91cc6455cbee5081db0ce8155,
title = "Microscopic velocimetry with a scaled-up model for evaluating a flow field over cultured endothelial cells",
abstract = "A microscopic velocimetry technique for evaluating the flow field over cultured endothelial cells was developed. Flow around a cell model scaled up by a factor of 100 was visualized by using an optical microscope and was quantified by using particle-tracking velocimetry. Wall shear stress on the model surface was determined from a two-dimensional velocity field interpolated from measured velocity vectors. Accuracy of the velocimetry was verified by measuring the flow over a sinusoidal cell model that had a wall shear stress profile analytically determined with linear perturbation theory. Comparison of the experimental results with the analytical solution revealed that the total error of the measured wall shear stress was 6 percent.",
author = "Shuichiro Fukushima and Takaaki Deguchi and Makoto Kaibara and Kotaro Oka and Kazuo Tanishita",
year = "2002",
doi = "10.1115/1.1449490",
language = "English",
volume = "124",
pages = "176--179",
journal = "Journal of Biomechanical Engineering",
issn = "0148-0731",
publisher = "American Society of Mechanical Engineers(ASME)",
number = "2",

}

TY - JOUR

T1 - Microscopic velocimetry with a scaled-up model for evaluating a flow field over cultured endothelial cells

AU - Fukushima, Shuichiro

AU - Deguchi, Takaaki

AU - Kaibara, Makoto

AU - Oka, Kotaro

AU - Tanishita, Kazuo

PY - 2002

Y1 - 2002

N2 - A microscopic velocimetry technique for evaluating the flow field over cultured endothelial cells was developed. Flow around a cell model scaled up by a factor of 100 was visualized by using an optical microscope and was quantified by using particle-tracking velocimetry. Wall shear stress on the model surface was determined from a two-dimensional velocity field interpolated from measured velocity vectors. Accuracy of the velocimetry was verified by measuring the flow over a sinusoidal cell model that had a wall shear stress profile analytically determined with linear perturbation theory. Comparison of the experimental results with the analytical solution revealed that the total error of the measured wall shear stress was 6 percent.

AB - A microscopic velocimetry technique for evaluating the flow field over cultured endothelial cells was developed. Flow around a cell model scaled up by a factor of 100 was visualized by using an optical microscope and was quantified by using particle-tracking velocimetry. Wall shear stress on the model surface was determined from a two-dimensional velocity field interpolated from measured velocity vectors. Accuracy of the velocimetry was verified by measuring the flow over a sinusoidal cell model that had a wall shear stress profile analytically determined with linear perturbation theory. Comparison of the experimental results with the analytical solution revealed that the total error of the measured wall shear stress was 6 percent.

UR - http://www.scopus.com/inward/record.url?scp=0036104835&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0036104835&partnerID=8YFLogxK

U2 - 10.1115/1.1449490

DO - 10.1115/1.1449490

M3 - Article

C2 - 12002126

AN - SCOPUS:0036104835

VL - 124

SP - 176

EP - 179

JO - Journal of Biomechanical Engineering

JF - Journal of Biomechanical Engineering

SN - 0148-0731

IS - 2

ER -